Vickers by Danfoss02-329268

02-329268

Vickers D08 Solenoid Valve
Item #102087188
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-329268
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Maintain 5 to 8 Nm (4 to 6 ft lb) maximum torque on valve tube nut
  • over-tightening may cause failure
Spool Code 8
Temperature Range [Max] 230 °F
Tank Port Rating 5000
Manual Override Option Code None
Spool Indicator Switch Code None
Coil Rating Code B
Response Type Standard Response
Gauge Ports Code None
Compatible Fluids Petroleum Oil
Mechanical Options Code None
Surge Suppressor/Damper Code None
Voltage & Frequency 110/120 VAC - 50/60 Hz
Manual Override Plain Override
Spool Control Modification Code None
Valve Type Standard-Duty
Reducer Module No
Model No. DG5V-8-S-8C-R-VM-FW-B-10
AC/DC AC
Function 3-Position Spring Centered
EN Code None
Electrical Connector Code None
No. of Stages Two Stage
Pressure Port Check Valve Code R
Design No. 10
Pilot Valve Type CETOP 3, Standard Performance
Reducer Module Code None
Operation Pilot Operated
Surge Suppressor/Damper None
Pilot/Drain Internal Pilot/External Drain
Overrides Plain Override Solenoid Ends
Gauge Port SAE-4
Seal Material Buna-N
Mechanical Options None
Leakage Standard Performance
Coil Type Code F
Fluid Cleanliness 19/17/14 micron
Mounting Subplate/Manifold Mount
Pilot Drain Code None
Solenoid Energization Code V
Body Material Ductile Iron
Housing Code W
Port Restrictor Plugs None
Gauge Port Thread Type 7/16 - 20 UNF, SAE Thread
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Indicator Lights No
Electrical Options Code None
Rated Flow [Max] 175 gal/min
Solenoid Indicator Lights Code None
Response Type Code None
Port T Pressure Rating 5000 psi
NFPA Size D08
Pilot Valve Type Code S
Actuator Type Solenoid
Crossover All Ports Open, Restricted
Pressure [Max] 5000 psi
Center Position P to T, A & B Blocked
Electrical Connection No Connector
Pressure Port Check Valve Pressure 50 psi
Electrical Options None
Solenoid Double
Actuation Identification Solenoid A, Solenoid B
Temperature Range [Min] -40 °F
Performance Standard Performance
Spool Spring Arrangement Code C
Pilot Pressure Code None
Port Restrictor Plug Code None
Weight 35.0 LB