Vickers D08 Solenoid Valve
Item #102084212
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-329270
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
EN Code None
Electrical Connector Code None
Response Type Code None
Gauge Ports Code None
Manual Override Plain Override
Tank Port Rating 5000
Spool Indicator Switch Code None
Rated Flow [Max] 185 gal/min
Coil Rating Code B
Electrical Options Code None
Design No. 10
Manual Override Option Code None
Pressure [Max] 5000 psi
Electrical Connection No Connector
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Center Position P to T, A & B Blocked
Mechanical Options None
Port T Pressure Rating 5000 psi
NFPA Size D08
Pilot Valve Type Code S
Function 3-Position Spring Centered
Gauge Port SAE-4
Spool Control Modification Code None
Solenoid Double
Valve Type Standard-Duty
Operation Pilot Operated
Actuator Type Solenoid
Port Restrictor Plug Code None
Crossover All Ports Open, Restricted
Pressure Port Check Valve Pressure 50 psi
Spool Spring Arrangement Code C
Mechanical Options Code None
Voltage & Frequency 110/120 VAC - 50/60 Hz
Solenoid Indicator Lights Code None
Surge Suppressor/Damper Code None
Pressure Port Check Valve Code R
Seal Material Buna-N
Spool Code 8
Electrical Options None
Response Type Standard Response
Pilot/Drain External Pilot/Internal Drain
Pilot Pressure Code None
Reducer Module N/A
Overrides Plain Override Solenoid Ends
Pilot Drain Code T
Housing Code W
Solenoid Energization Code V
Reducer Module Code None
Indicator Lights No
Coil Type Code F
Pilot Valve Type CETOP 3, Standard Performance
Surge Suppressor/Damper None
Port Restrictor Plugs None
AC/DC AC
Model No. DG5V-8-S-8C-T-R-VM-FW-B-10
Weight 35.0 LB