Vickers by Danfoss02-329283

02-329283

Vickers D08 Solenoid Valve
Item #101977676
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset Function
Vickers by Danfoss02-329283
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Maintain 5 to 8 Nm (4 to 6 ft lb) maximum torque on valve tube nut
  • over-tightening may cause failure
Reducer Module Code None
Actuator Type Solenoid
Housing Code W
Spool Indicator Switch Code None
Valve Type Standard-Duty
Spool Control Modification Code None
Pressure Port Check Valve Code None
NFPA Size D08
Gauge Port SAE-4
Electrical Options Code None
Surge Suppressor/Damper Code None
Solenoid Indicator Lights Code None
Voltage & Frequency 110/120 VAC - 50/60 Hz
Mechanical Options Code None
Pilot/Drain External Pilot/Internal Drain
Pressure [Max] 5000 psi
Electrical Connection No Connector
Tank Port Rating 5000
Manual Override Plain Override
Surge Suppressor/Damper None
Seal Material Buna-N
Center Position All Ports Open Over Tapers
Response Type Standard Response
Solenoid Single
Electrical Connector Code None
Port Restrictor Plug Code None
Model No. DG5V-8-S-9A-M-FW-B-10
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Gauge Ports Code None
Pilot Drain Code None
Manual Override Option Code None
Overrides Plain Override Solenoid Ends
Electrical Options None
Rated Flow [Max] 185 gal/min
AC/DC AC
Pilot Pressure Code None
Response Type Code None
Pilot Valve Type Code S
Pilot Valve Type CETOP 3, Standard Performance
Crossover All Ports Open
Operation Pilot Operated
Indicator Lights No
Coil Rating Code B
Port T Pressure Rating 5000 psi
Coil Type Code F
Mechanical Options None
Design No. 10
Pressure Port Check Valve Pressure N/A
Solenoid Energization Code None
Spool Spring Arrangement Code A
Port Restrictor Plugs None
EN Code None
Function 2-Position Spring Offset
Spool Code 9
Reducer Module N/A
Weight 35.0 LB