Vickers by Danfoss02-329283

02-329283

Vickers D08 Solenoid Valve
Item #101977676
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset Function
Vickers by Danfoss02-329283
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Maintain 5 to 8 Nm (4 to 6 ft lb) maximum torque on valve tube nut
  • over-tightening may cause failure
Solenoid Indicator Lights Code None
Operation Pilot Operated
Electrical Connector Code None
EN Code None
Pilot Pressure Code None
Mechanical Options Code None
Crossover All Ports Open
Surge Suppressor/Damper None
Spool Code 9
Electrical Options None
Gauge Port SAE-4
Solenoid Energization Code None
Pressure [Max] 5000 psi
Function 2-Position Spring Offset
Response Type Standard Response
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Pilot Drain Code None
Indicator Lights No
NFPA Size D08
Spool Spring Arrangement Code A
Housing Code W
Valve Type Standard-Duty
Coil Rating Code B
Spool Indicator Switch Code None
Pilot Valve Type CETOP 3, Standard Performance
Design No. 10
Electrical Connection No Connector
Pressure Port Check Valve Code None
Reducer Module N/A
Coil Type Code F
Tank Port Rating 5000
Actuator Type Solenoid
Response Type Code None
Electrical Options Code None
Port Restrictor Plugs None
Pressure Port Check Valve Pressure N/A
Surge Suppressor/Damper Code None
Gauge Ports Code None
Manual Override Plain Override
Manual Override Option Code None
Overrides Plain Override Solenoid Ends
AC/DC AC
Rated Flow [Max] 185 gal/min
Port Restrictor Plug Code None
Seal Material Buna-N
Center Position All Ports Open Over Tapers
Voltage & Frequency 110/120 VAC - 50/60 Hz
Reducer Module Code None
Solenoid Single
Mechanical Options None
Spool Control Modification Code None
Pilot/Drain External Pilot/Internal Drain
Pilot Valve Type Code S
Port T Pressure Rating 5000 psi
Model No. DG5V-8-S-9A-M-FW-B-10
Weight 35.0 LB