Vickers by Danfoss02-330933

02-330933

Vickers D08 Solenoid Valve
Item #101975652
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-330933
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Not for air service
Pilot Drain Code None
Spool Code 52
Rated Flow [Max] 175 gal/min
Mechanical Options None
Response Type Code None
Pilot Pressure Code E
Model No. DG5V-8-S-52C-E-M-U-B-10
Coil Type ISO 4400 (Din 43650) Connector
Pressure Port Check Valve Pressure N/A
Tank Port Rating 5000
Operation Pilot Operated
Electrical Connection No Connector
Coil Rating Code B
Manual Override Option Code None
Body Material Ductile Iron
Solenoid Energization Code None
Center Position Closed Center, Regen Solenoid A
AC/DC AC
Electrical Options Code None
Voltage & Frequency 110/120 VAC - 50/60 Hz
Port T Pressure Rating 5000 psi
Compatible Fluids Petroleum Oil
Gauge Port Thread Type 7/16 - 20 UNF, SAE Thread
Leakage Standard Performance
Function 3-Position Spring Centered
Manual Override Plain Override
Reducer Module No
Performance Standard Performance
Port Restrictor Plug Code None
Solenoid Double
Pilot/Drain External Pilot/External Drain
Pilot Valve Type CETOP 3, Standard Performance
Mechanical Options Code None
Design No. 10
Seal Material Buna-N
Indicator Lights No
Spool Indicator Switch Code None
Gauge Port SAE-4
Pressure [Max] 5000 psi
EN Code None
Spool Spring Arrangement Code C
Fluid Cleanliness 19/17/14 micron
Housing Code None
Solenoid Indicator Lights Code None
Pressure Port Check Valve Code None
Overrides Plain Override Solenoid Ends
Pilot Valve Type Code S
Valve Type Standard-Duty
Reducer Module Code None
NFPA Size D08
Temperature Range [Min] -40 °F
Mounting Subplate/Manifold Mount
Port Restrictor Plugs None
Crossover Closed Center All Ports
Electrical Connector Code None
Surge Suppressor/Damper None
Surge Suppressor/Damper Code None
Gauge Ports Code None
Coil Type Code U
Response Type Standard Response
Actuation Identification Solenoid A, Solenoid B
Temperature Range [Max] 230 °F
No. of Stages Two Stage
Spool Control Modification Code None
Electrical Options None
Actuator Type Solenoid
Weight 35.0 LB