Vickers D03 Solenoid Valve

02-333947

Vickers D03 Solenoid Valve
Item #101912676
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • These solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. The 60-design series has been specially designed and developed to cover expanded demands in the industry as well as the many traditional uses of the earlier designs.

features

  • Efficient control of greater hydraulic powers without increasing solenoid power consumption
  • Multi-fluid capability without the need to change seals
  • Solenoid coils can be changed quickly and easily without leakage from the hydraulic system
  • Compact, cost-effective system design when used with Vickers SystemStak valves and subplates
  • Up to 21 gpm at 5,000 psi
  • Valve mounting face conforms to ISO 4401, size 03, and is compatible with related international standards
Spool Indicator Switch Code None
Mounting Subplate/Manifold Mount
Port T Code 7
Port Restrictor Plugs None
Function 3-Position Spring Centered
Fluid Cleanliness 19/17/14 micron
Surge Suppressor/Damper Code None
Valve Type High-Performance
Solenoid Double
AC/DC DC
Temperature Range [Min] -4 °F
Manual Override Plain Override
Electrical Options None
Coil Type Connector Fitted
Response Time 28 to 45 ms
Seal Material Buna-N
Rated Flow [Max] 20 gal/min
Overrides No Overrides
Spool Shift Timing N/A
Voltage & Frequency 12 VDC
Pilot Valve Type N/A
Tank Port Rating 3046
Leakage Standard Performance
EN Code None
Pilot/Drain None
Watt Rating 30 W
Coil Rating Code G
No. of Stages Single Stage
Body Material Gray Iron
Crossover P Blocked, A or B to T
Solenoid Indicator Lights Code None
NFPA Size D03
Housing Code None
Indicator Lights No
Coil Type Code U1
Actuator Type Solenoid
Design No. 60
Electrical Connector Code None
Response Type Standard Response
Compatible Fluids Petroleum Oil
Cycle Rate [Max] N/A
Function Code 6
Port Restrictor Plug Code None
Performance High Performance
Temperature Range [Max] 158 °F
Actuation Identification Solenoid A, Solenoid B
Pressure Port Check Valve Pressure N/A
Spool Code 6
Reducer Module No
Pressure [Max] 5000 psi
Operation Solenoid Operated
Mechanical Options None
Spool Spring Arrangement Code C
Electrical Connection Connector Fitted
Port T Pressure Rating 3000 psi
Center Position P Blocked, A & B to T
Solenoid Code G
Surge Suppressor/Damper None
Model No. DG4V 3 6C M U1 G7 60
Manual Override Option Code None
Solenoid Energization Code None
Weight 5.0 LB