Skip to content Skip to navigation menu
Vickers by Danfoss02-337244

02-337244

Vickers D07 Solenoid Valve
Item #101975620
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D07 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset Function
Vickers by Danfoss02-337244
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D07 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset Function

description

  • Two-stage directional valves with an integrally mounted DG4V-3(S)-60 pilot valve. These valves are generally used to control the direction of flow in a hydraulic circuit. This in turn would control the movement of a work cylinder or the rotation of a fluid motor.

applications

  • Suitable for the most demanding industrial applications with flow capacities up to 227 l/min (60 U.S. gpm) and rated pressure of 210 bar (3,000 psi)

features

  • Solid cast body and core passages for maximum strength and minimal pressure drop
Overrides Plain Override Solenoid Ends
Port T Pressure Rating 1450 psi
Pressure Port Check Valve Code None
Mounting Screw Option Code N/A
Solenoid Single
Electrical Connector Code None
Crossover All Ports Blocked
Housing Code W
Solenoid Indicator Lights Code None
Model No. DG5S4-042A-X-M-FW-B5-60
Function 2-Position Spring Offset
Coil Rating Code B
Rated Flow [Max] 60 gal/min
Pressure Port Check Valve Pressure N/A
Spool Indicator Switch Code None
Electrical Options None
Coil Type Code F
Surge Suppressor/Damper None
Seal Material Buna-N
Response Type Fast Response
Solenoid Energization Code None
Pilot/Drain External Pilot/Internal Drain
Electrical Options Code None
Spool Control Modification Code None
Response Type Code X
Electrical Connection No Connector
Pressure [Max] 3000 psi
Pilot Valve Type N/A
Operation Solenoid Operated
EN Code None
Indicator Lights No
Mechanical Options None
Tank Port Rating 1450
Voltage & Frequency 110/120 VAC - 50/60 Hz
Pilot Drain Code None
Valve Type Standard-Duty
Reducer Module N/A
Assembly Code None
Port Restrictor Plugs None
Actuator Type Solenoid
AC/DC AC
Design No. 60
NFPA Size D07
Manual Override Plain Override
Spool Spring Arrangement Code A
Manual Override Option Code None
Center Position All Ports Blocked
Pilot Valve Tank Pressure Rating Code 5
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Pilot Pressure Code None
Port Restrictor Plug Code None
Spool Code 2
Weight 15.0 LB