Skip to content Skip to navigation menu
Vickers by Danfoss02-337735

02-337735

Vickers D08 Solenoid Valve
Item #102196355
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset Function
Vickers by Danfoss02-337735
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Drives requiring high Overload Service Factors may need heavy-duty web type sheaves
Response Type Code None
AC/DC AC
Seal Material Buna-N
Pilot Drain Code None
Spool Indicator Switch Code None
Indicator Lights No
Electrical Options None
Pressure Port Check Valve Pressure N/A
Operation Pilot Operated
Rated Flow [Max] 185 gal/min
Port Restrictor Plug Code None
EN Code None
Spool Spring Arrangement Code A
Solenoid Single
Design No. 10
Gauge Ports Code None
Overrides Plain Override Solenoid Ends
Reducer Module N/A
Pressure Port Check Valve Code None
Coil Rating Code D
Crossover All Ports Blocked
Mechanical Options Code None
Spool Control Modification Code 2
Manual Override Plain Override
Valve Type Standard-Duty
Reducer Module Code None
Solenoid Energization Code None
Coil Type Code U
Gauge Port SAE-4
Voltage & Frequency 220/240 VAC - 50/60 Hz
Model No. DG5V-8-S-2A-2-M-U-D-10
Surge Suppressor/Damper Code None
Function 2-Position Spring Offset
Mechanical Options Adjust Pilot Chokes on Both Ends
Surge Suppressor/Damper None
Electrical Connection No Connector
Center Position All Ports Blocked
Solenoid Indicator Lights Code None
Pilot Pressure Code None
Spool Code 2
Port Restrictor Plugs None
Pilot Valve Type Code S
Actuator Type Solenoid
Port T Pressure Rating 5000 psi
Electrical Connector Code None
Pilot/Drain External Pilot/Internal Drain
Pressure [Max] 5000 psi
NFPA Size D08
Electrical Options Code None
Housing Code None
Coil Type DIN 43650
Tank Port Rating 5000
Pilot Valve Type CETOP 3, Standard Performance
Manual Override Option Code None
Response Type Standard Response
Weight 35.0 LB
We're here for you
with Service Centers across the country -
We have your back
Close Compare List Open Compare List Toggle

Product Comparison