Vickers by Danfoss02-338240

02-338240

Vickers D08 Solenoid Valve
Item #102172654
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-338240
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Should not be exposed to ketones, chlorinated hydrocarbons and esters found in lacquer thinners, degreasers, paint strippers, etc., which may cause the backing to swell or curl
Port T Pressure Rating 5000 psi
Port Restrictor Plug Code None
Seal Material Buna-N
Pilot Pressure Code None
Gauge Port SAE-4
Solenoid Indicator Lights Code L
Pressure Port Check Valve Pressure N/A
Port Restrictor Plugs None
Electrical Options Code None
Body Material Ductile Iron
Gauge Port Thread Type 7/16 - 20 UNF, SAE Thread
Response Type Code None
Reducer Module No
Voltage & Frequency 110/120 VAC - 50/60 Hz
Actuator Type Solenoid
Performance Standard Performance
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Indicator Lights Yes
Manual Override Plain Override
EN Code None
Electrical Options None
Solenoid Energization Code None
Fluid Cleanliness 19/17/14 micron
Electrical Connector Code T
Spool Indicator Switch Code None
Surge Suppressor/Damper Code None
Solenoid Double
Mounting Subplate/Manifold Mount
Model No. DG5V-8-S-3C-M-FTWL-B-10
Actuation Identification Solenoid A, Solenoid B
No. of Stages Two Stage
Crossover All Ports Blocked, or P & B Blocked, A to T
Design No. 10
Spool Code 3
Mechanical Options Code None
Overrides Plain Override Solenoid Ends
Temperature Range [Min] -40 °F
Coil Rating Code B
Coil Type Code F
Spool Spring Arrangement Code C
Center Position P & B Blocked, A to T
Housing Code W
Function 3-Position Spring Centered
Rated Flow [Max] 175 gal/min
Pilot Valve Type CETOP 3, Standard Performance
Pilot Valve Type Code S
Spool Control Modification Code None
Tank Port Rating 5000
NFPA Size D08
Surge Suppressor/Damper None
Compatible Fluids Petroleum Oil
Valve Type Standard-Duty
Pressure Port Check Valve Code None
Pilot/Drain Internal Pilot/External Drain
Pilot Drain Code None
Response Type Standard Response
AC/DC AC
Pressure [Max] 5000 psi
Mechanical Options None
Reducer Module Code None
Electrical Connection Wired Terminal Block
Leakage Standard Performance
Temperature Range [Max] 230 °F
Manual Override Option Code None
Gauge Ports Code None
Operation Pilot Operated
Weight 35.0 LB