Skip to content Skip to navigation menu
Vickers by Danfoss02-338243

02-338243

Vickers D08 Solenoid Valve
Item #102170613
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset Function
Vickers by Danfoss02-338243
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Steel housings must be used for operating pressures above 3,000 psi
Spool Control Modification Code None
NFPA Size D08
Housing Code None
No. of Stages Two Stage
Spool Indicator Switch Code None
Pressure Port Check Valve Code None
Pressure Port Check Valve Pressure N/A
Indicator Lights No
Reducer Module No
Temperature Range [Max] 230 °F
Watt Rating 30 W
Mechanical Options None
Seal Material Buna-N
Tank Port Rating 5000
Function 2-Position Spring Offset
Surge Suppressor/Damper None
Surge Suppressor/Damper Code None
Actuation Identification Solenoid B
Response Type Code None
Coil Rating Code H
Temperature Range [Min] -40 °F
Operation Pilot Operated
Coil Type ISO 4400 (Din 43650) Connector
Pilot Valve Type CETOP 3, High Performance
Crossover All Ports Blocked
EN Code None
Solenoid Single
Electrical Options None
Port T Pressure Rating 5000 psi
Solenoid Indicator Lights Code None
Gauge Ports Code None
Rated Flow [Max] 175 gal/min
Pressure [Max] 5000 psi
Valve Type Standard-Duty
Electrical Connection No Connector
Center Position All Ports Blocked
Port Restrictor Plug Code None
Pilot Valve Type Code H
Solenoid Energization Code None
Gauge Port SAE-4
Pilot Drain Code None
AC/DC DC
Electrical Options Code None
Reducer Module Code None
Performance High Performance
Port Restrictor Plugs None
Response Type Standard Response
Gauge Port Thread Type 7/16 - 20 UNF, SAE Thread
Mounting Subplate/Manifold Mount
Actuator Type Solenoid
Spool Code 2
Mechanical Options Code None
Manual Override Option Code None
Pilot/Drain Internal Pilot/External Drain
Compatible Fluids Petroleum Oil
Manual Override Plain Override
Model No. DG5V-8-H-2A-M-U-H-10
Design No. 10
Overrides Plain Override Solenoid Ends
Fluid Cleanliness 19/17/14 micron
Coil Type Code U
Voltage & Frequency 24 VDC
Body Material Ductile Iron
Spool Spring Arrangement Code A
Leakage High Performance
Electrical Connector Code None
Pilot Pressure Code None
Weight 35.0 LB