Vickers by Danfoss02-339127

02-339127

Vickers D08 Solenoid Valve
Item #102171327
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-339127
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
Tank Port Rating 5000
Pilot Pressure Code None
Electrical Connector Code None
Gauge Port SAE-4
EN Code None
Port Restrictor Plug Code None
Solenoid Energization Code None
Center Position P Blocked, A & B to T
Spool Spring Arrangement Code C
Electrical Connection No Connector
Response Type Standard Response
Solenoid Double
NFPA Size D08
Manual Override Plain Override
Port Restrictor Plugs None
Voltage & Frequency 110/120 VAC - 50/60 Hz
Design No. 10
Pilot/Drain External Pilot/Internal Drain
Spool Indicator Switch Code None
Electrical Options None
Valve Type Standard-Duty
Function 3-Position Spring Centered
Model No. DG5V-8-S-6C-2-M-FW-B-10
Pressure Port Check Valve Code None
Port T Pressure Rating 5000 psi
Pressure Port Check Valve Pressure N/A
Reducer Module Code None
Response Type Code None
Housing Code W
Pressure [Max] 5000 psi
Pilot Drain Code None
Spool Code 6
Rated Flow [Max] 185 gal/min
Solenoid Indicator Lights Code None
Pilot Valve Type CETOP 3, Standard Performance
Pilot Valve Type Code S
Actuator Type Solenoid
Operation Pilot Operated
AC/DC AC
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Spool Control Modification Code 2
Surge Suppressor/Damper Code None
Coil Type Code F
Manual Override Option Code None
Electrical Options Code None
Seal Material Buna-N
Reducer Module N/A
Crossover P Blocked, A or B to T
Surge Suppressor/Damper None
Indicator Lights No
Gauge Ports Code None
Mechanical Options Adjust Pilot Chokes on Both Ends
Coil Rating Code B
Overrides Plain Override Solenoid Ends
Mechanical Options Code None
Weight 35.0 LB