Vickers by Danfoss02-339451

02-339451

Vickers D08 Solenoid Valve
Item #102173967
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-339451
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Cannot be used in air systems where compressors are lubricated with fire-resistant fluids, such as phosphate ester and di-ester types
Pilot/Drain External Pilot/Internal Drain
Manual Override Option Code None
Housing Code None
Port Restrictor Plugs None
Pilot Valve Type Code H
Design No. 10
Reducer Module Code None
Coil Rating Code D
Pilot Valve Type CETOP 3, High Performance
Solenoid Double
Operation Pilot Operated
Response Type Code None
Actuator Type Solenoid
Spool Indicator Switch Code None
Port T Pressure Rating 5000 psi
Gauge Ports Code None
Rated Flow [Max] 185 gal/min
Port Restrictor Plug Code None
Surge Suppressor/Damper None
Electrical Options None
Pilot Drain Code None
Solenoid Energization Code None
Pilot Pressure Code E
Reducer Module N/A
Manual Override Plain Override
Crossover All Ports Open
Function 3-Position Spring Centered
Mechanical Options Code None
Mechanical Options None
Pressure Port Check Valve Code None
Electrical Connection No Connector
Surge Suppressor/Damper Code None
Voltage & Frequency 220/240 VAC - 50/60 Hz
Spool Control Modification Code None
Tank Port Rating 5000
Model No. DG5V-8-H-0C-E-M-U-D-10
Center Position All Ports Open
Response Type Standard Response
Pressure [Max] 5000 psi
Solenoid Indicator Lights Code None
Coil Type DIN 43650
Electrical Options Code None
Electrical Connector Code None
Spool Code 0
NFPA Size D08
Valve Type Standard-Duty
Coil Type Code U
Overrides Plain Override Solenoid Ends
Gauge Port SAE-4
EN Code None
AC/DC AC
Seal Material Buna-N
Spool Spring Arrangement Code C
Indicator Lights No
Pressure Port Check Valve Pressure N/A
Weight 35.0 LB