- Solenoid Actuated Valve
- Pilot Operated Operation
- D08 NFPA Size
- Double Solenoid
- 3-Position Spring Centered Function
description
- DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.
caution
- Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
| Function | 3-Position Spring Centered |
| Overrides | Plain Override Solenoid Ends |
| Seal Material | Buna-N |
| Pilot/Drain | External Pilot/Internal Drain |
| Valve Type | Standard-Duty |
| Crossover | All Ports Open, Restricted |
| Solenoid | Double |
| Voltage & Frequency | 110/120 VAC - 50/60 Hz |
| Reducer Module | No |
| Electrical Options Code | None |
| Housing Code | W |
| Electrical Options | None |
| Reducer Module Code | None |
| Surge Suppressor/Damper | None |
| Solenoid Energization Code | V |
| Port T Pressure Rating | 5000 psi |
| Spool Indicator Switch Code | None |
| Design No. | 10 |
| Pilot Pressure Code | None |
| Spool Spring Arrangement Code | C |
| Tank Port Rating | 5000 |
| Indicator Lights | No |
| Electrical Connection | No Connector |
| NFPA Size | D08 |
| Pilot Valve Type | CETOP 3, High Performance |
| Body Material | Gray Iron |
| Fluid Cleanliness | 19/17/14 micron |
| Coil Type | Flying Leads, 1/2 in NPT Thread Wiring Housing |
| Port Restrictor Plugs | None |
| Surge Suppressor/Damper Code | None |
| Performance | High Performance |
| Compatible Fluids | Petroleum Oil |
| Pilot Drain Code | None |
| Model No. | DG5V-8-H-8C-VM-FW-B-10 |
| Pilot Valve Type Code | H |
| Spool Code | 8 |
| Spool Control Modification Code | None |
| Gauge Port Thread Type | 7/16 - 20 UNF, SAE Thread |
| Coil Type Code | F |
| Pressure Port Check Valve Pressure | N/A |
| Spool Center Condition | A Port and Double Offset sensing switch on B Port |
| AC/DC | AC |
| Solenoid Indicator Lights Code | None |
| EN Code | None |
| Port Restrictor Plug Code | None |
| Response Type Code | None |
| Mechanical Options | None |
| Pressure Port Check Valve Code | None |
| Coil Rating Code | B |
| Manual Override Option Code | None |
| Center Position | P to T, A & B Blocked |
| Operation | Pilot Operated |
| Response Type | Standard Response |
| Mechanical Options Code | None |
| No. of Stages | Two Stage |
| Mounting | Subplate/Manifold Mount |
| Leakage | Standard Performance |
| Gauge Ports Code | None |
| Electrical Connector Code | None |
| Rated Flow [Max] | 175 gal/min |
| Gauge Port | SAE-4 |
| Pressure [Max] | 5000 psi |
| Actuator Type | Solenoid |
| Manual Override | Plain Override |
| Weight | 35.0 LB |