Vickers by Danfoss02-339932

02-339932

Vickers D08 Solenoid Valve
Item #101920163
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position, 4-Way, Spring Centered Function
Vickers by Danfoss02-339932
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position, 4-Way, Spring Centered Function

description

  • The DG5S8 are two-stage directional valves with an integrally-mounted DG4V3S pilot valve. These valves are used to control the direction of flow in hydraulic circuits.

compliances

  • 0

caution

  • Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
Manual Override Plain Override
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Leakage Standard Performance
Port Restrictor Plugs None
Body Material Gray Iron
Function 3-Position, 4-Way, Spring Centered
Operation Pilot Operated
Spool Control Modification Code None
Spool Code 2
Reducer Module No
Response Type Standard Response
Valve Type Standard-Duty
Spool Spring Arrangement Code C
Pressure Port Check Valve Code None
Pressure Port Check Valve Pressure N/A
Solenoid Double
Indicator Lights Yes
Model No. DG5V-8-H-2C-T-M-FTWL-B-10
Coil Type Code F
Tank Port Rating 5000
Port T Pressure Rating 5000 psi
Reducer Module Code None
Surge Suppressor/Damper None
Design No. 10
Port Restrictor Plug Code None
Compatible Fluids Petroleum Oil
Surge Suppressor/Damper Code None
Electrical Options None
EN Code None
Mechanical Options Code None
Seal Material Buna-N
Actuator Type Solenoid
Gauge Port Thread Type 7/16 - 20 UNF, SAE Thread
No. of Stages Two Stage
Mounting Subplate/Manifold Mount
Performance High Performance
Voltage & Frequency 110/120 VAC - 50/60 Hz
Pilot/Drain External Pilot/Internal Drain
Crossover All Ports Blocked
AC/DC AC
Pilot Drain Code T
Gauge Ports Code None
Pilot Valve Type CETOP 3, High Performance
Rated Flow [Max] 175 gal/min
Fluid Cleanliness 19/17/14 micron
Pilot Pressure Code None
Overrides Plain Override Solenoid Ends
Gauge Port SAE-4
Pilot Valve Type Code H
NFPA Size D08
Electrical Connection Wired Terminal Block
Manual Override Option Code None
Mechanical Options None
Coil Rating Code B
Center Position All Ports Blocked
Electrical Options Code None
Spool Indicator Switch Code None
Spool Center Condition A Port and Double Offset sensing switch on B Port
Housing Code W
Response Type Code None
Pressure [Max] 5000 psi
Electrical Connector Code T
Solenoid Indicator Lights Code L
Solenoid Energization Code None
Weight 35.0 LB