Vickers by Danfoss02-339932

02-339932

Vickers D08 Solenoid Valve
Item #101920163
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position, 4-Way, Spring Centered Function
Vickers by Danfoss02-339932
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position, 4-Way, Spring Centered Function

description

  • The DG5S8 are two-stage directional valves with an integrally-mounted DG4V3S pilot valve. These valves are used to control the direction of flow in hydraulic circuits.

compliances

  • 0

caution

  • Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
Gauge Port Thread Type 7/16 - 20 UNF, SAE Thread
Spool Spring Arrangement Code C
Electrical Options Code None
Manual Override Option Code None
Electrical Options None
Port Restrictor Plugs None
Valve Type Standard-Duty
Solenoid Energization Code None
Pilot Valve Type Code H
Function 3-Position, 4-Way, Spring Centered
Body Material Gray Iron
Mounting Subplate/Manifold Mount
Operation Pilot Operated
Tank Port Rating 5000
EN Code None
AC/DC AC
Electrical Connection Wired Terminal Block
Crossover All Ports Blocked
Surge Suppressor/Damper Code None
Pressure Port Check Valve Pressure N/A
Reducer Module Code None
Voltage & Frequency 110/120 VAC - 50/60 Hz
Pressure [Max] 5000 psi
Pressure Port Check Valve Code None
Port T Pressure Rating 5000 psi
Spool Code 2
Surge Suppressor/Damper None
Performance High Performance
Center Position All Ports Blocked
NFPA Size D08
Leakage Standard Performance
Model No. DG5V-8-H-2C-T-M-FTWL-B-10
Seal Material Buna-N
Spool Control Modification Code None
Response Type Code None
Pilot Valve Type CETOP 3, High Performance
Mechanical Options Code None
Electrical Connector Code T
Reducer Module No
Pilot Drain Code T
Overrides Plain Override Solenoid Ends
Rated Flow [Max] 175 gal/min
Manual Override Plain Override
Design No. 10
Actuator Type Solenoid
Mechanical Options None
Pilot/Drain External Pilot/Internal Drain
Solenoid Double
Spool Center Condition A Port and Double Offset sensing switch on B Port
Port Restrictor Plug Code None
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Coil Rating Code B
Spool Indicator Switch Code None
Gauge Ports Code None
Pilot Pressure Code None
Indicator Lights Yes
Gauge Port SAE-4
Solenoid Indicator Lights Code L
Housing Code W
Response Type Standard Response
Coil Type Code F
No. of Stages Two Stage
Fluid Cleanliness 19/17/14 micron
Compatible Fluids Petroleum Oil
Weight 35.0 LB