DG4V-3S Series Solenoid Operated Directional Valve

02-342060

DG4V-3S Series Solenoid Operated Directional Valve
Item #101906045
  • Double Sol Valve
  • Std-Duty
  • D03
  • 3-Pos Spring Centered
  • 110/120 VAC - 50/60 Hz
  • 1/2 NPT Conduit Box, 1/2 NPT Thread Wiring Housing
  • Center Pos: P Blocked, A & B to T
  • Crossover: P Blocked, A or B to T
  • w/Lights
  • 10.50 gpm Max Flow
+ Show More + Show Less
DG4V-3S Series Solenoid Operated Directional Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Double Sol Valve
  • Std-Duty
  • D03
  • 3-Pos Spring Centered
  • 110/120 VAC - 50/60 Hz

description

  • These solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. The 60-design series has been specially designed and developed to cover expanded demands in the industry as well as the many traditional uses of the earlier designs.

features

  • Efficient control of greater hydraulic powers without increasing solenoid power consumption
  • Multi-fluid capability without the need to change seals
  • Solenoid coils can be changed quickly and easily without leakage from the hydraulic system
  • Compact, cost-effective system design when used with Vickers SystemStak valves and subplates
  • Up to 10.5 gpm at 5,000 psi
  • Valve mounting face conforms to ISO 4401, size 03, and is compatible with related international standards
Valve Type Standard-Duty
Center Position P Blocked, A & B to T
Coil Type Flying Leads, 1/2 NPT Thread Wiring Housing
Coil Type Code F
Spool Shift Timing N/A
Pilot/Drain None
Response Type Standard Response
Port T Pressure Rating 1500 psi
Mechanical Options None
Manual Override Option Code H
Port Restrictor Plug Code None
Surge Suppressor/Damper Code None
Design No. 60
Overrides No Overrides
Electrical Connector Code None
Solenoid Energization Code None
Solenoid Indicator Lights Code L
Function Code 6
Operation Solenoid Operated
Electrical Connection No Connector
Cycle Rate [Max] N/A
Solenoid Double
Rated Flow [Max] 10.5 gal/min
Coil Rating Code B
Seal Material Buna-N
Reducer Module N/A
Spool Spring Arrangement Code C
Actuator Type Solenoid
Spool Indicator Switch Code None
AC/DC AC
Spool Code 6
Pilot Valve Type N/A
Port Restrictor Plugs None
Voltage & Frequency 110/120 VAC – 50/60 Hz
Electrical Options None
EN Code EN21
NFPA Size D03
Housing Code W
Function 3-Position Spring Centered
Indicator Lights Yes
Pressure Port Check Valve Pressure N/A
Pressure [Max] 5075 psi
Crossover P Blocked, A or B to T
Surge Suppressor/Damper None
Solenoid Code B
Port T Code 5
Weight 5.0 LB