Vickers by Danfoss02-342098

02-342098

Vickers D08 Solenoid Valve
Item #101909037
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-342098
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
Temperature Range [Min] -40 °F
Spool Code 6
Solenoid Energization Code None
Mounting Subplate/Manifold Mount
Pilot Valve Type Code H
Overrides Plain Override Solenoid Ends
Electrical Options None
Model No. DG5V-8-H-6C-2-T-M-FTWL-B-10
Indicator Lights Yes
Manual Override Plain Override
Reducer Module No
Spool Indicator Switch Code None
Operation Pilot Operated
Pilot Valve Type CETOP 3, High Performance
Seal Material Buna-N
Pressure Port Check Valve Code None
Function 3-Position Spring Centered
Actuator Type Solenoid
Gauge Port Thread Type 7/16 - 20 UNF, SAE Thread
Gauge Port SAE-4
Performance High Performance
Port Restrictor Plugs None
Port Restrictor Plug Code None
Valve Type Standard-Duty
Port T Pressure Rating 5000 psi
Leakage High Performance
Electrical Options Code None
Electrical Connector Code T
Coil Type Code F
Compatible Fluids Petroleum Oil
AC/DC AC
Surge Suppressor/Damper Code None
Actuation Identification Solenoid A, Solenoid B
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Tank Port Rating 5000
Response Type Code None
Spool Control Modification Code 2
Fluid Cleanliness 19/17/14 micron
Pilot/Drain External Pilot/Internal Drain
Design No. 10
Mechanical Options Adjust Pilot Chokes on Both Ends
Housing Code W
Mechanical Options Code None
NFPA Size D08
Rated Flow [Max] 175 gal/min
Spool Spring Arrangement Code C
Pilot Pressure Code None
Manual Override Option Code None
Voltage & Frequency 110/120 VAC - 50/60 Hz
Crossover P Blocked, A or B to T
Pilot Drain Code T
Gauge Ports Code None
Response Type Standard Response
Solenoid Indicator Lights Code L
Solenoid Double
Reducer Module Code None
Temperature Range [Max] 230 °F
Center Position P Blocked, A & B to T
Electrical Connection Wired Terminal Block
Body Material Ductile Iron
Pressure [Max] 5000 psi
No. of Stages Two Stage
Coil Rating Code B
Pressure Port Check Valve Pressure N/A
Surge Suppressor/Damper None
EN Code None
Weight 35.0 LB