Vickers by Danfoss02-342106

02-342106

Vickers D08 Solenoid Valve
Item #101909098
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-342106
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Design allows for possible axial shifting of components relative to the shaft, so utilize this device where exact positioning is not critical
Body Material Gray Iron
Port T Pressure Rating 5000 psi
Electrical Options None
Model No. DG5V-8-H-8C-E-VM-FW-B-10
Actuator Type Solenoid
Spool Center Condition A Port and Double Offset sensing switch on B Port
Fluid Cleanliness 19/17/14 micron
Surge Suppressor/Damper Code None
AC/DC AC
Overrides Plain Override Solenoid Ends
Spool Control Modification Code None
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Gauge Ports Code None
Coil Rating Code B
Indicator Lights No
Surge Suppressor/Damper None
Port Restrictor Plug Code None
Spool Code 8
Voltage & Frequency 110/120 VAC - 50/60 Hz
Compatible Fluids Petroleum Oil
EN Code None
Manual Override Plain Override
Tank Port Rating 5000
Function 3-Position Spring Centered
Solenoid Indicator Lights Code None
Mechanical Options Code None
Seal Material Buna-N
Housing Code W
Response Type Standard Response
Pressure Port Check Valve Code None
Pilot Valve Type Code H
Pressure [Max] 5000 psi
Performance High Performance
No. of Stages Two Stage
Pilot/Drain External Pilot/Internal Drain
Pilot Valve Type CETOP 3, High Performance
Solenoid Double
Pilot Drain Code None
Operation Pilot Operated
Electrical Options Code None
Coil Type Code F
Reducer Module No
Design No. 10
Pressure Port Check Valve Pressure N/A
Manual Override Option Code None
Solenoid Energization Code V
Crossover All Ports Open, Restricted
NFPA Size D08
Port Restrictor Plugs None
Mounting Subplate/Manifold Mount
Spool Spring Arrangement Code C
Response Type Code None
Rated Flow [Max] 175 gal/min
Mechanical Options None
Gauge Port Thread Type 7/16 - 20 UNF, SAE Thread
Gauge Port SAE-4
Leakage Standard Performance
Pilot Pressure Code E
Center Position P to T, A & B Blocked
Spool Indicator Switch Code None
Valve Type Standard-Duty
Electrical Connection No Connector
Electrical Connector Code None
Reducer Module Code None
Weight 35.0 LB