Vickers by Danfoss02-342167

02-342167

Vickers D10 Solenoid Valve
Item #101907094
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D10 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset Function
Vickers by Danfoss02-342167
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D10 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset Function

applications

  • Used to control large flows, to 1,100 l/min (290 US gpm)

features

  • Valve has been computer flow modeled in the core passages of the solid cast body to provide maximum flow at the lowest possible pressure drop
  • Endurance tested to 10 million cycles and fatigue tested to NFPA specifications without failure to ensure the highest reliability in applications requiring high flows and pressure
  • Offers a wide variety spool and spring arrangements, pilot choke adjustments, integral check valves, and port orifices to meet most system requirements
  • High force solenoids and centering springs ensure consistent shifting through a wide range of pressure and silting extremes
Rated Flow [Max] 290 gal/min
Pilot Pressure Code E
Pressure Port Check Valve Code None
Housing Code None
Port Restrictor Plug Code None
Mechanical Options None
Spool Spring Arrangement Code A
Actuator Type Solenoid
Solenoid Single
Pilot Pressure [Max] 3000 psi
Assembly Code None
Response Type Code None
AC/DC DC
Port Restrictor Plugs None
Indicator Lights No
Overrides Plain Override Solenoid Ends
Electrical Connector Code None
Spool Code 2
Manual Override Plain Override
Gauge Ports Code None
Electrical Options Code None
Gauge Port SAE-4
Coil Type DIN 43650
Surge Suppressor/Damper Code None
Operation Pilot Operated
Pilot Drain Code T
Reducer Module Code None
Pilot/Drain External Pilot/Internal Drain
Tank Port Rating 3000
Pilot Valve Type CETOP 3, High Performance
Solenoid Energization Code None
NFPA Size D10
Center Position All Ports Blocked
Reducer Module N/A
Model No. DG5V-10-H-2A-E-T-M-U-H-10
Valve Type Standard-Duty
Crossover All Ports Blocked
Voltage & Frequency 24 VDC
Function 2-Position Spring Offset
Seal Material Buna-N
Solenoid Indicator Lights Code None
Surge Suppressor/Damper None
Coil Rating Code H
EN Code None
Port T Pressure Rating 3000 psi
Spool Control Modification Code None
Electrical Connection No Connector
Electrical Options None
Manual Override Option Code None
Coil Type Code U
Pilot Valve Type Code H
Design No. 10
Pressure [Max] 5000 psi
Response Type Standard Response
Pressure Port Check Valve Pressure N/A
Weight 100.0 LB