- Solenoid Actuated Valve
- Pilot Operated Operation
- D08 NFPA Size
- Double Solenoid
- 3-Position Spring Centered Function
description
- DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.
caution
- Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
| Overrides | Plain Override Solenoid Ends |
| Pilot Valve Type | CETOP 3, Standard Performance |
| Reducer Module | No |
| Tank Port Rating | 5000 |
| Fluid Cleanliness | 19/17/14 micron |
| Mounting | Subplate/Manifold Mount |
| Solenoid Indicator Lights Code | L |
| Pressure Port Check Valve Code | None |
| Pressure [Max] | 5000 psi |
| Actuator Type | Solenoid |
| Response Type | Standard Response |
| Pilot/Drain | External Pilot/External Drain |
| Crossover | All Ports Blocked |
| No. of Stages | Two Stage |
| Pilot Valve Type Code | S |
| Mechanical Options | None |
| Response Type Code | None |
| Pilot Drain Code | None |
| Gauge Port | SAE-4 |
| Compatible Fluids | Petroleum Oil |
| Model No. | DG5V-8-S-4C-E-VM-FTWL-B-10 |
| Coil Type Code | F |
| Seal Material | Buna-N |
| Surge Suppressor/Damper | None |
| EN Code | None |
| Actuation Identification | Solenoid A, Solenoid B |
| Performance | Standard Performance |
| Reducer Module Code | None |
| Electrical Connection | Wired Terminal Block |
| Spool Code | 4 |
| Spool Indicator Switch Code | None |
| Pressure Port Check Valve Pressure | N/A |
| Spool Spring Arrangement Code | C |
| AC/DC | AC |
| Valve Type | Standard-Duty |
| Rated Flow [Max] | 175 gal/min |
| Electrical Options Code | None |
| Port Restrictor Plug Code | None |
| Operation | Pilot Operated |
| Coil Rating Code | B |
| Function | 3-Position Spring Centered |
| Gauge Port Thread Type | 7/16 - 20 UNF, SAE Thread |
| Coil Type | Flying Leads, 1/2 in NPT Thread Wiring Housing |
| Indicator Lights | Yes |
| Gauge Ports Code | None |
| Surge Suppressor/Damper Code | None |
| Voltage & Frequency | 110/120 VAC - 50/60 Hz |
| Port Restrictor Plugs | None |
| Port T Pressure Rating | 5000 psi |
| Temperature Range [Min] | -40 °F |
| Housing Code | W |
| Manual Override Option Code | None |
| Pilot Pressure Code | E |
| Body Material | Ductile Iron |
| NFPA Size | D08 |
| Center Position | Tandem P to T |
| Spool Control Modification Code | None |
| Mechanical Options Code | None |
| Electrical Options | None |
| Leakage | Standard Performance |
| Manual Override | Plain Override |
| Electrical Connector Code | T |
| Solenoid Energization Code | V |
| Temperature Range [Max] | 230 °F |
| Design No. | 10 |
| Solenoid | Double |
| Weight | 35.0 LB |