Vickers by Danfoss02-344058

02-344058

Vickers D08 Solenoid Valve
Item #102100083
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Single Solenoid
  • 2-Position Spring Centered, End To Center Function
Vickers by Danfoss02-344058
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Single Solenoid
  • 2-Position Spring Centered, End To Center Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
Coil Type Code U
NFPA Size D08
EN Code None
Mechanical Options Code None
Response Type Code None
Seal Material Buna-N
Surge Suppressor/Damper Code None
Port Restrictor Plugs None
Pressure Port Check Valve Pressure N/A
Electrical Connector Code None
Electrical Connection No Connector
Rated Flow [Max] 185 gal/min
Overrides Plain Override Solenoid Ends
Reducer Module N/A
Spool Control Modification Code None
Pressure [Max] 5000 psi
Response Type Standard Response
Reducer Module Code None
Mechanical Options None
Gauge Ports Code None
Solenoid Indicator Lights Code None
Pilot Valve Type Code H
Gauge Port SAE-4
Tank Port Rating 5000
Model No. DG5V-8-H-6B-M-U-H-10
Pilot/Drain External Pilot/Internal Drain
Spool Code 6
Indicator Lights No
Coil Type DIN 43650
Actuator Type Solenoid
Manual Override Plain Override
Port T Pressure Rating 5000 psi
Pilot Pressure Code None
Valve Type Standard-Duty
Pilot Valve Type CETOP 3, High Performance
Solenoid Energization Code None
Spool Spring Arrangement Code B
AC/DC DC
Pilot Drain Code None
Solenoid Single
Design No. 10
Voltage & Frequency 24 VDC
Center Position P Blocked, A & B to T
Electrical Options Code None
Manual Override Option Code None
Surge Suppressor/Damper None
Pressure Port Check Valve Code None
Housing Code None
Electrical Options None
Port Restrictor Plug Code None
Spool Indicator Switch Code None
Operation Pilot Operated
Function 2-Position Spring Centered, End To Center
Coil Rating Code H
Crossover P Blocked, A or B to T
Weight 35.0 LB