Vickers D08 Solenoid Valve
Item #102061831
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-344333
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Temperatures not to exceed 170 °F (77 °C)
Indicator Lights No
Spool Code 2
Surge Suppressor/Damper None
Gauge Ports Code None
Pressure [Max] 5000 psi
Solenoid Double
Solenoid Indicator Lights Code None
Pilot Drain Code T
Model No. DG5V-8-H-2C-T-M-U-B-10
Reducer Module Code None
EN Code None
Operation Pilot Operated
Mechanical Options Code None
Body Material Gray Iron
Port T Pressure Rating 5000 psi
Pressure Port Check Valve Pressure N/A
Coil Type Code U
Tank Port Rating 5000
Design No. 10
Seal Material Buna-N
Function 3-Position Spring Centered
Solenoid Energization Code None
Spool Spring Arrangement Code C
Electrical Connector Code None
Surge Suppressor/Damper Code None
Gauge Port Thread Type 7/16 - 20 UNF, SAE Thread
Electrical Options None
Manual Override Option Code None
Actuator Type Solenoid
Housing Code None
Pilot Valve Type CETOP 3, High Performance
No. of Stages Two Stage
Pilot/Drain External Pilot/Internal Drain
Crossover All Ports Blocked
Pressure Port Check Valve Code None
AC/DC AC
Port Restrictor Plugs None
Valve Type Standard-Duty
Coil Rating Code B
Pilot Pressure Code None
Rated Flow [Max] 175 gal/min
Mechanical Options None
Spool Center Condition A Port and Double Offset sensing switch on B Port
Fluid Cleanliness 20/18/15 micron
Voltage & Frequency 110/120 VAC - 50/60 Hz
Gauge Port SAE-4
Response Type Standard Response
Pilot Valve Type Code H
Leakage Standard Performance
Overrides Plain Override Solenoid Ends
Response Type Code None
Electrical Connection No Connector
Manual Override Plain Override
Spool Indicator Switch Code None
NFPA Size D08
Performance High Performance
Electrical Options Code None
Mounting Subplate/Manifold Mount
Spool Control Modification Code None
Reducer Module No
Coil Type ISO 4400 (Din 43650) Connector
Compatible Fluids Petroleum Oil
Port Restrictor Plug Code None
Center Position All Ports Blocked
Weight 35.0 LB