- Solenoid Actuated Valve
- Pilot Operated Operation
- D08 NFPA Size
- Double Solenoid
- 3-Position Spring Centered Function
description
- DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.
caution
- Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
| Port T Pressure Rating | 5000 psi |
| Spool Indicator Switch Code | None |
| Gauge Ports Code | None |
| Surge Suppressor/Damper | None |
| Spool Code | 6 |
| Solenoid Indicator Lights Code | None |
| Electrical Options | None |
| Actuator Type | Solenoid |
| Voltage & Frequency | 110/120 VAC - 50/60 Hz |
| Compatible Fluids | Petroleum Oil |
| Coil Rating Code | B |
| Function | 3-Position Spring Centered |
| Temperature Range [Max] | 230 °F |
| Tank Port Rating | 5000 |
| Leakage | High Performance |
| Pilot Pressure Code | E |
| Seal Material | Buna-N |
| Spool Control Modification Code | None |
| Spool Spring Arrangement Code | C |
| Response Type | Standard Response |
| EN Code | None |
| Temperature Range [Min] | -40 °F |
| Reducer Module Code | None |
| Coil Type | ISO 4400 (Din 43650) Connector |
| Model No. | DG5V-8-H-6C-E-M-U-B-10 |
| Solenoid | Double |
| Overrides | Plain Override Solenoid Ends |
| Crossover | P Blocked, A or B to T |
| AC/DC | AC |
| Gauge Port | SAE-4 |
| Pilot Drain Code | None |
| Electrical Connection | No Connector |
| Pilot Valve Type Code | H |
| Pressure Port Check Valve Pressure | N/A |
| Reducer Module | No |
| Coil Type Code | U |
| NFPA Size | D08 |
| Manual Override Option Code | None |
| Housing Code | None |
| Pilot Valve Type | CETOP 3, High Performance |
| Fluid Cleanliness | 19/17/14 micron |
| Mechanical Options Code | None |
| No. of Stages | Two Stage |
| Actuation Identification | Solenoid A, Solenoid B |
| Mounting | Subplate/Manifold Mount |
| Rated Flow [Max] | 175 gal/min |
| Pressure Port Check Valve Code | None |
| Valve Type | Standard-Duty |
| Surge Suppressor/Damper Code | None |
| Electrical Options Code | None |
| Operation | Pilot Operated |
| Solenoid Energization Code | None |
| Port Restrictor Plugs | None |
| Center Position | P Blocked, A & B to T |
| Response Type Code | None |
| Body Material | Ductile Iron |
| Design No. | 10 |
| Port Restrictor Plug Code | None |
| Manual Override | Plain Override |
| Mechanical Options | None |
| Performance | High Performance |
| Electrical Connector Code | None |
| Pressure [Max] | 5000 psi |
| Gauge Port Thread Type | 7/16 - 20 UNF, SAE Thread |
| Indicator Lights | No |
| Pilot/Drain | External Pilot/External Drain |
| Weight | 35.0 LB |