Vickers D10 Solenoid Valve
Item #101910324
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D10 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-356214
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D10 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

applications

  • Used to control large flows, to 1,100 l/min (290 US gpm)

features

  • High force solenoids and centering springs ensure consistent shifting through a wide range of pressure and silting extremes
  • Offers a wide variety spool and spring arrangements, pilot choke adjustments, integral check valves, and port orifices to meet most system requirements
  • Endurance tested to 10 million cycles and fatigue tested to NFPA specifications without failure to ensure the highest reliability in applications requiring high flows and pressure
  • Valve has been computer flow modeled in the core passages of the solid cast body to provide maximum flow at the lowest possible pressure drop
Overrides Plain Override Solenoid Ends
EN Code None
Pressure [Max] 5000 psi
Spool Control Modification Code None
Spool Spring Arrangement Code C
Pilot Valve Type Code H
Indicator Lights No
Coil Type DIN 43650
Gauge Port SAE-4
Solenoid Energization Code None
Electrical Options None
Design No. 10
Voltage & Frequency 24 VDC
Tank Port Rating 3000
Pressure Port Check Valve Code None
Center Position P & B Blocked, A to T
Pilot Drain Code None
Port Restrictor Plug Code None
Manual Override Plain Override
Housing Code None
Rated Flow [Max] 290 gal/min
Electrical Connection No Connector
Function 3-Position Spring Centered
Seal Material Buna-N
Port T Pressure Rating 3000 psi
Mechanical Options None
Surge Suppressor/Damper None
Response Type Standard Response
Operation Pilot Operated
NFPA Size D10
Valve Type Standard-Duty
Manual Override Option Code None
Reducer Module Code None
Electrical Options Code None
Response Type Code None
Actuator Type Solenoid
Crossover All Ports Blocked, or P & B Blocked, A to T
Coil Rating Code H
Port Restrictor Plugs None
Spool Code 3
Pilot Pressure Code E
Coil Type Code U
Surge Suppressor/Damper Code None
Electrical Connector Code None
Model No. DG5V-10-H-3C-E-M-U-H-10
Pilot/Drain External Pilot/Internal Drain
Solenoid Indicator Lights Code None
Gauge Ports Code None
Assembly Code None
Solenoid Double
Reducer Module N/A
Pilot Pressure [Max] 3000 psi
Pressure Port Check Valve Pressure N/A
AC/DC DC
Pilot Valve Type CETOP 3, High Performance
Weight 100.0 LB