- Solenoid Actuated Valve
- Pilot Operated Operation
- D08 NFPA Size
- Double Solenoid
- 3-Position Spring Centered Function
description
- DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.
caution
- Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
| Actuator Type | Solenoid |
| Body Material | Ductile Iron |
| Pressure [Max] | 5000 psi |
| Spool Control Modification Code | 2 |
| Reducer Module Code | None |
| NFPA Size | D08 |
| Fluid Cleanliness | 19/17/14 micron |
| Compatible Fluids | Petroleum Oil |
| Pressure Port Check Valve Code | None |
| Port Restrictor Plug Code | None |
| Design No. | 10 |
| Electrical Connection | No Connector |
| Coil Rating Code | B |
| Solenoid | Double |
| Function | 3-Position Spring Centered |
| Solenoid Energization Code | None |
| Temperature Range [Min] | -40 °F |
| Gauge Port | SAE-4 |
| Surge Suppressor/Damper Code | None |
| Port T Pressure Rating | 5000 psi |
| Overrides | Plain Override Solenoid Ends |
| Leakage | High Performance |
| Pressure Port Check Valve Pressure | N/A |
| Pilot Valve Type Code | H |
| EN Code | None |
| Port Restrictor Plugs | None |
| Spool Spring Arrangement Code | C |
| Solenoid Indicator Lights Code | None |
| Crossover | P Blocked, A or B to T |
| Rated Flow [Max] | 175 gal/min |
| Electrical Options | None |
| Spool Code | 6 |
| Actuation Identification | Solenoid A, Solenoid B |
| Pilot Valve Type | CETOP 3, High Performance |
| Tank Port Rating | 5000 |
| Manual Override Option Code | None |
| Gauge Port Thread Type | 7/16 - 20 UNF, SAE Thread |
| Gauge Ports Code | None |
| Response Type Code | None |
| Operation | Pilot Operated |
| Electrical Connector Code | None |
| Mounting | Subplate/Manifold Mount |
| Spool Indicator Switch Code | None |
| Response Type | Standard Response |
| Performance | High Performance |
| Mechanical Options | Adjust Pilot Chokes on Both Ends |
| Valve Type | Standard-Duty |
| Electrical Options Code | None |
| Pilot Pressure Code | None |
| Model No. | DG5V-8-H-6C-2-M-U-B-10 |
| AC/DC | AC |
| Surge Suppressor/Damper | None |
| Seal Material | Buna-N |
| Coil Type Code | U |
| Coil Type | ISO 4400 (Din 43650) Connector |
| Voltage & Frequency | 110/120 VAC - 50/60 Hz |
| Housing Code | None |
| No. of Stages | Two Stage |
| Indicator Lights | No |
| Temperature Range [Max] | 230 °F |
| Reducer Module | No |
| Manual Override | Plain Override |
| Pilot Drain Code | None |
| Mechanical Options Code | None |
| Center Position | P Blocked, A & B to T |
| Pilot/Drain | Internal Pilot/External Drain |
| Weight | 35.0 LB |