Vickers D10 Solenoid Valve
Item #101906902
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D10 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-356594
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D10 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

applications

  • Used to control large flows, to 1,100 l/min (290 US gpm)

features

  • Valve has been computer flow modeled in the core passages of the solid cast body to provide maximum flow at the lowest possible pressure drop
  • Endurance tested to 10 million cycles and fatigue tested to NFPA specifications without failure to ensure the highest reliability in applications requiring high flows and pressure
  • Offers a wide variety spool and spring arrangements, pilot choke adjustments, integral check valves, and port orifices to meet most system requirements
  • High force solenoids and centering springs ensure consistent shifting through a wide range of pressure and silting extremes
Center Position All Ports Blocked
Mechanical Options Adjust Stroke on Both Ends
Electrical Options None
Rated Flow [Max] 290 gal/min
Reducer Module Code None
Spool Spring Arrangement Code C
Crossover All Ports Blocked
Electrical Connection No Connector
Pilot Valve Type Code H
Model No. DG5V-10-H-2C-1-T-M-U-H-10
Housing Code None
Electrical Connector Code None
Spool Control Modification Code 1
Actuator Type Solenoid
Surge Suppressor/Damper Code None
Gauge Ports Code None
Coil Type Code U
Port Restrictor Plugs None
Solenoid Energization Code None
Voltage & Frequency 24 VDC
Manual Override Option Code None
Pilot/Drain External Pilot/Internal Drain
Solenoid Double
Solenoid Indicator Lights Code None
NFPA Size D10
Port Restrictor Plug Code None
Spool Code 2
Gauge Port SAE-4
Assembly Code None
Operation Pilot Operated
Port T Pressure Rating 3000 psi
Coil Rating Code H
Design No. 10
Reducer Module N/A
Electrical Options Code None
Manual Override Plain Override
Pilot Drain Code T
Function 3-Position Spring Centered
Tank Port Rating 3000
Coil Type DIN 43650
Response Type Code None
Overrides Plain Override Solenoid Ends
Pressure Port Check Valve Code None
Response Type Standard Response
EN Code None
Pressure Port Check Valve Pressure N/A
Indicator Lights No
Pilot Pressure [Max] 3000 psi
Pilot Valve Type CETOP 3, High Performance
AC/DC DC
Seal Material Buna-N
Pressure [Max] 5000 psi
Pilot Pressure Code None
Valve Type Standard-Duty
Surge Suppressor/Damper None
Weight 100.0 LB