Vickers by Danfoss02-357561

02-357561

Vickers D08 Solenoid Valve
Item #101909572
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-357561
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
Mechanical Options None
Response Type Standard Response
Leakage Standard Performance
Operation Pilot Operated
Electrical Connector Code None
Tank Port Rating 5000
Surge Suppressor/Damper Code None
Spool Code 3
AC/DC AC
Pilot/Drain External Pilot/Internal Drain
Port Restrictor Plugs None
Solenoid Double
NFPA Size D08
EN Code None
Solenoid Energization Code None
Temperature Range [Min] -40 °F
Mounting Subplate/Manifold Mount
Indicator Lights No
Coil Rating Code B
Reducer Module Code None
Coil Type ISO 4400 (Din 43650) Connector
Overrides Plain Override Solenoid Ends
Housing Code None
Actuation Identification Solenoid A, Solenoid B
Mechanical Options Code None
Port T Pressure Rating 5000 psi
Gauge Port SAE-4
Body Material Ductile Iron
Seal Material Buna-N
Pressure [Max] 5000 psi
Spool Spring Arrangement Code C
Spool Control Modification Code None
Model No. DG5V-8-S-3C-E-M-U-B-10
Pressure Port Check Valve Code None
Manual Override Option Code None
Valve Type Standard-Duty
Crossover All Ports Blocked, or P & B Blocked, A to T
Pilot Drain Code None
No. of Stages Two Stage
Electrical Options Code None
Gauge Ports Code None
Surge Suppressor/Damper None
Performance Standard Performance
Reducer Module No
Pilot Valve Type CETOP 3, Standard Performance
Gauge Port Thread Type 7/16 - 20 UNF, SAE Thread
Manual Override Plain Override
Compatible Fluids Petroleum Oil
Rated Flow [Max] 175 gal/min
Electrical Connection No Connector
Port Restrictor Plug Code None
Design No. 10
Temperature Range [Max] 230 °F
Spool Indicator Switch Code None
Solenoid Indicator Lights Code None
Fluid Cleanliness 19/17/14 micron
Coil Type Code U
Actuator Type Solenoid
Function 3-Position Spring Centered
Voltage & Frequency 110/120 VAC - 50/60 Hz
Pilot Pressure Code E
Response Type Code None
Center Position P & B Blocked, A to T
Pilot Valve Type Code S
Electrical Options None
Pressure Port Check Valve Pressure N/A
Weight 35.0 LB