- Solenoid Actuated Valve
- Pilot Operated Operation
- D08 NFPA Size
- Double Solenoid
- 3-Position Spring Centered Function
description
- DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.
caution
- Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
| Response Type Code | X |
| Pressure Port Check Valve Code | None |
| Port Restrictor Plugs | None |
| EN Code | None |
| Rated Flow [Max] | 185 gal/min |
| Pressure [Max] | 5000 psi |
| Model No. | DG5V-8-S-4C-X-E-VM-FTWL-B-10 |
| Solenoid Indicator Lights Code | L |
| Mechanical Options Code | None |
| Function | 3-Position Spring Centered |
| Solenoid Energization Code | V |
| Coil Rating Code | B |
| Valve Type | Standard-Duty |
| Tank Port Rating | 5000 |
| Housing Code | W |
| Manual Override | Plain Override |
| Surge Suppressor/Damper Code | None |
| Actuator Type | Solenoid |
| Spool Indicator Switch Code | None |
| Reducer Module Code | None |
| Indicator Lights | Yes |
| Pilot Drain Code | None |
| Response Type | Fast Response |
| Spool Spring Arrangement Code | C |
| Spool Control Modification Code | None |
| Port T Pressure Rating | 5000 psi |
| AC/DC | AC |
| Manual Override Option Code | None |
| Gauge Port | SAE-4 |
| Electrical Connection | Wired Terminal Block |
| Spool Code | 4 |
| Center Position | Tandem P to T |
| Seal Material | Buna-N |
| Pilot Valve Type | CETOP 3, Standard Performance |
| NFPA Size | D08 |
| Solenoid | Double |
| Pressure Port Check Valve Pressure | N/A |
| Electrical Options | None |
| Surge Suppressor/Damper | None |
| Reducer Module | N/A |
| Coil Type Code | F |
| Electrical Options Code | None |
| Pilot Valve Type Code | S |
| Pilot/Drain | External Pilot/Internal Drain |
| Operation | Pilot Operated |
| Crossover | All Ports Blocked |
| Gauge Ports Code | None |
| Coil Type | Flying Leads, 1/2 in NPT Thread Wiring Housing |
| Voltage & Frequency | 110/120 VAC - 50/60 Hz |
| Port Restrictor Plug Code | None |
| Mechanical Options | None |
| Electrical Connector Code | T |
| Design No. | 10 |
| Pilot Pressure Code | E |
| Overrides | Plain Override Solenoid Ends |
| Weight | 35.0 LB |