Vickers by Danfoss02-363070

02-363070

Vickers D08 Solenoid Valve
Item #101910592
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-363070
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Design allows for possible axial shifting of components relative to the shaft, so utilize this device where exact positioning is not critical
Port Restrictor Plugs None
AC/DC AC
Surge Suppressor/Damper Code None
Operation Pilot Operated
Solenoid Double
Pilot Pressure Code E
Response Type Standard Response
Spool Indicator Switch Code None
Temperature Range [Max] 230 °F
Fluid Cleanliness 19/17/14 micron
Mounting Subplate/Manifold Mount
Reducer Module Code None
Coil Type Code F
Crossover All Ports Open, Restricted
Pressure Port Check Valve Code None
Rated Flow [Max] 175 gal/min
Actuation Identification Solenoid A, Solenoid B
Solenoid Indicator Lights Code None
Manual Override Option Code None
Gauge Port SAE-4
Pressure [Max] 5000 psi
Pilot Drain Code None
Port Restrictor Plug Code None
Pilot Valve Type CETOP 3, High Performance
Spool Spring Arrangement Code C
Pressure Port Check Valve Pressure N/A
Design No. 10
Mechanical Options Code None
Leakage High Performance
Spool Control Modification Code 2
Valve Type Standard-Duty
Reducer Module No
Port T Pressure Rating 5000 psi
Solenoid Energization Code V
Mechanical Options Adjust Pilot Chokes on Both Ends
Electrical Connection No Connector
Temperature Range [Min] -40 °F
Compatible Fluids Petroleum Oil
Coil Rating Code B
Indicator Lights No
Response Type Code None
Voltage & Frequency 110/120 VAC - 50/60 Hz
Overrides Plain Override Solenoid Ends
Housing Code W
Function 3-Position Spring Centered
Body Material Ductile Iron
NFPA Size D08
Tank Port Rating 5000
Pilot/Drain External Pilot/External Drain
Gauge Port Thread Type 7/16 - 20 UNF, SAE Thread
Model No. DG5V-8-H-8C-2-E-VM-FW-B-10
EN Code None
Center Position P to T, A & B Blocked
Actuator Type Solenoid
Electrical Connector Code None
Seal Material Buna-N
Electrical Options None
Surge Suppressor/Damper None
Spool Code 8
Pilot Valve Type Code H
Electrical Options Code None
Gauge Ports Code None
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
No. of Stages Two Stage
Manual Override Plain Override
Performance High Performance
Weight 35.0 LB