- Solenoid Actuated Valve
- Pilot Operated Operation
- D08 NFPA Size
- Double Solenoid
- 3-Position Spring Centered Function
description
- DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.
caution
- Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
| Pilot Drain Code | T |
| Valve Type | Standard-Duty |
| Seal Material | Buna-N |
| Pressure [Max] | 5000 psi |
| Solenoid Energization Code | V |
| Function | 3-Position Spring Centered |
| Gauge Port Thread Type | 7/16 - 20 UNF, SAE Thread |
| Manual Override Option Code | None |
| Model No. | DG5V-8-H-8C-T-R-VM-FW-B-10 |
| Coil Rating Code | B |
| Spool Indicator Switch Code | None |
| Pressure Port Check Valve Code | R |
| Voltage & Frequency | 110/120 VAC - 50/60 Hz |
| Solenoid | Double |
| Electrical Connection | No Connector |
| Spool Code | 8 |
| Spool Spring Arrangement Code | C |
| Coil Type | Flying Leads, 1/2 in NPT Thread Wiring Housing |
| Solenoid Indicator Lights Code | None |
| Electrical Options | None |
| Surge Suppressor/Damper Code | None |
| AC/DC | AC |
| Mounting | Subplate/Manifold Mount |
| Temperature Range [Max] | 230 °F |
| Body Material | Ductile Iron |
| Design No. | 10 |
| Spool Control Modification Code | None |
| Temperature Range [Min] | -40 °F |
| Operation | Pilot Operated |
| Overrides | Plain Override Solenoid Ends |
| Fluid Cleanliness | 19/17/14 micron |
| Gauge Port | SAE-4 |
| No. of Stages | Two Stage |
| Indicator Lights | No |
| Reducer Module Code | None |
| Port T Pressure Rating | 5000 psi |
| Mechanical Options | None |
| Pressure Port Check Valve Pressure | 50 psi |
| Port Restrictor Plug Code | None |
| Actuation Identification | Solenoid A, Solenoid B |
| Reducer Module | No |
| Electrical Options Code | None |
| Mechanical Options Code | None |
| Response Type Code | None |
| Pilot Valve Type Code | H |
| Leakage | High Performance |
| Pilot Valve Type | CETOP 3, High Performance |
| Center Position | P to T, A & B Blocked |
| NFPA Size | D08 |
| Performance | High Performance |
| Rated Flow [Max] | 175 gal/min |
| EN Code | None |
| Gauge Ports Code | None |
| Actuator Type | Solenoid |
| Port Restrictor Plugs | None |
| Crossover | All Ports Open, Restricted |
| Surge Suppressor/Damper | None |
| Response Type | Standard Response |
| Pilot/Drain | Internal Pilot/Internal Drain |
| Coil Type Code | F |
| Electrical Connector Code | None |
| Compatible Fluids | Petroleum Oil |
| Housing Code | W |
| Pilot Pressure Code | None |
| Tank Port Rating | 5000 |
| Manual Override | Plain Override |
| Weight | 35.0 LB |