Vickers by Danfoss02-364358

02-364358

Vickers D10 Solenoid Valve
Item #101907772
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D10 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset Function
Vickers by Danfoss02-364358
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D10 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset Function

applications

  • Used to control large flows, to 1,100 l/min (290 US gpm)

features

  • Valve has been computer flow modeled in the core passages of the solid cast body to provide maximum flow at the lowest possible pressure drop
  • Endurance tested to 10 million cycles and fatigue tested to NFPA specifications without failure to ensure the highest reliability in applications requiring high flows and pressure
  • Offers a wide variety spool and spring arrangements, pilot choke adjustments, integral check valves, and port orifices to meet most system requirements
  • High force solenoids and centering springs ensure consistent shifting through a wide range of pressure and silting extremes
Pilot Drain Code T
Pilot Valve Type Code H
NFPA Size D10
Reducer Module N/A
Voltage & Frequency 24 VDC
Gauge Port SAE-4
Coil Type Code U
Spool Control Modification Code None
Solenoid Energization Code None
Reducer Module Code None
Electrical Connection No Connector
Pilot Pressure Code None
Indicator Lights No
Pressure [Max] 5000 psi
Port T Pressure Rating 3000 psi
Crossover All Ports Blocked
Response Type Code None
Housing Code None
Seal Material Buna-N
Manual Override Option Code None
Electrical Options Code None
AC/DC DC
Center Position All Ports Blocked
Gauge Ports Code None
Coil Rating Code H
Surge Suppressor/Damper Code None
Mechanical Options None
Coil Type DIN 43650
Actuator Type Solenoid
Valve Type Standard-Duty
Port Restrictor Plugs None
Surge Suppressor/Damper None
Design No. 10
Pilot Pressure [Max] 3000 psi
Electrical Connector Code None
Pilot/Drain External Pilot/Internal Drain
Pressure Port Check Valve Code None
Solenoid Single
Overrides Plain Override Solenoid Ends
Solenoid Indicator Lights Code None
Manual Override Plain Override
Response Type Standard Response
Operation Pilot Operated
Pilot Valve Type CETOP 3, High Performance
Tank Port Rating 3000
Rated Flow [Max] 290 gal/min
Port Restrictor Plug Code None
Function 2-Position Spring Offset
Electrical Options None
Spool Spring Arrangement Code A
Pressure Port Check Valve Pressure N/A
Assembly Code None
EN Code None
Model No. DG5V-10-H-2A-T-M-U-H-10
Spool Code 2
Weight 100.0 LB