Vickers by Danfoss02-390226

02-390226

Vickers D08 Solenoid Valve
Item #101910581
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-390226
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Design allows for possible axial shifting of components relative to the shaft, so utilize this device where exact positioning is not critical
Pressure [Max] 5000 psi
Gauge Ports Code None
Valve Type Standard-Duty
Operation Pilot Operated
AC/DC AC
Actuation Identification Solenoid A, Solenoid B
Performance High Performance
Manual Override Plain Override
Gauge Port SAE-4
Pilot Drain Code None
Port Restrictor Plugs None
Overrides Plain Override Solenoid Ends
Leakage High Performance
Reducer Module Code None
Spool Code 4
Solenoid Double
Gauge Port Thread Type 7/16 - 20 UNF, SAE Thread
Voltage & Frequency 110/120 VAC - 50/60 Hz
Indicator Lights No
Port T Pressure Rating 5000 psi
Pressure Port Check Valve Pressure 50 psi
No. of Stages Two Stage
Tank Port Rating 5000
Coil Type Code F
Surge Suppressor/Damper Code None
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Design No. 10
Solenoid Indicator Lights Code None
Temperature Range [Min] -40 °F
Spool Spring Arrangement Code C
Compatible Fluids Petroleum Oil
Electrical Options Code None
Pressure Port Check Valve Code R
Manual Override Option Code None
EN Code None
Electrical Connection No Connector
Pilot Valve Type CETOP 3, High Performance
Coil Rating Code B
Rated Flow [Max] 175 gal/min
Pilot Valve Type Code H
Function 3-Position Spring Centered
Crossover All Ports Blocked
Pilot/Drain Internal Pilot/External Drain
Actuator Type Solenoid
Mechanical Options Code None
Electrical Connector Code None
Spool Control Modification Code None
Spool Indicator Switch Code None
Pilot Pressure Code None
Center Position Tandem P to T
Seal Material Buna-N
Reducer Module No
Body Material Ductile Iron
NFPA Size D08
Model No. DG5V-8-H-4C-R-VM-FW-B-10
Response Type Code None
Mounting Subplate/Manifold Mount
Electrical Options None
Surge Suppressor/Damper None
Fluid Cleanliness 19/17/14 micron
Housing Code W
Mechanical Options None
Port Restrictor Plug Code None
Solenoid Energization Code V
Temperature Range [Max] 230 °F
Response Type Standard Response
Weight 35.0 LB