Skip to content Skip to navigation menu
Vickers by Danfoss836AN00080A

836AN00080A

Vickers D08 Solenoid Valve
Item #105715616
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Spring Centered Function
Vickers by Danfoss836AN00080A
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Spring Centered Function
Actuation Identification Solenoid A, Solenoid B
Pilot/Drain Internal Pilot/External Drain
Temperature Range [Min] -40 °F
Manual Override Plain Override
Spool Spring Arrangement Code C
Operation Pilot Operated
Voltage & Frequency 24 VDC
Rated Flow [Max] 175 gal/min
Compatible Fluids Petroleum Oil
Actuator Type Solenoid
Model No. DG5V-8-H-6C-M-FTWL-H-10
Seal Material Buna-N
Mounting Subplate/Manifold Mount
AC/DC DC
Temperature Range [Max] 230 °F
Performance High Performance
Fluid Cleanliness 19/17/14 micron
Reducer Module No
Function Spring Centered
Pressure [Max] 5000 psi
No. of Stages Two Stage
NFPA Size D08
Gauge Port Thread Type 7/16 - 20 UNF, SAE Thread
Body Material Ductile Iron
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Watt Rating 30 W
Indicator Lights Yes
Electrical Connection Wired Terminal Block
Leakage High Performance
Weight 0.0 LB