Skip to content Skip to navigation menu
Vickers D03 Solenoid Valve

859180

Vickers D03 Solenoid Valve
Item #101922877
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • These solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. The 60-design series has been specially designed and developed to cover expanded demands in the industry as well as the many traditional uses of the earlier designs.

features

  • Efficient control of greater hydraulic powers without increasing solenoid power consumption
  • Multi-fluid capability without the need to change seals
  • Solenoid coils can be changed quickly and easily without leakage from the hydraulic system
  • Compact, cost-effective system design when used with Vickers SystemStak valves and subplates
  • Up to 21 gpm at 5,000 psi
  • Valve mounting face conforms to ISO 4401, size 03, and is compatible with related international standards
Spool Shift Timing N/A
Rated Flow [Max] 20 gal/min
Function 3-Position Spring Centered
Indicator Lights No
Temperature Range [Min] -4 °F
Manual Override Plain Override
Leakage Standard Performance
Surge Suppressor/Damper None
Coil Type ISO 4400
Seal Material Buna-N
Spool Indicator Switch Code None
Reducer Module No
Solenoid Code C
Pilot Valve Type N/A
Port T Pressure Rating 3000 psi
Design No. 60
Tank Port Rating 3046
Pilot/Drain None
Temperature Range [Max] 158 °F
Fluid Cleanliness 19/17/14 micron
Operation Solenoid Operated
Model No. DG4V 3 6C M U C6 60
Pressure Port Check Valve Pressure N/A
Crossover P Blocked, A or B to T
Electrical Connector Code None
Port Restrictor Plugs None
Function Code 6
Spool Code 6
Actuator Type Solenoid
Solenoid Energization Code None
Overrides No Overrides
Actuation Identification Solenoid A, Solenoid B
Response Time 15 to 23 ms
Response Type Standard Response
Spool Spring Arrangement Code C
NFPA Size D03
Electrical Options None
Mounting Subplate/Manifold Mount
Mechanical Options None
Coil Type Code U
AC/DC AC
Performance High Performance
Voltage & Frequency 220/240 VAC - 50/60 Hz
Solenoid Indicator Lights Code None
Cycle Rate [Max] N/A
EN Code None
Electrical Connection DIN 43650
Center Position P Blocked, A & B to T
Valve Type High-Performance
Compatible Fluids Petroleum Oil
Manual Override Option Code None
Body Material Gray Iron
No. of Stages Single Stage
Solenoid Double
Pressure [Max] 5000 psi
Coil Rating Code C
Port Restrictor Plug Code None
Housing Code None
Surge Suppressor/Damper Code None
Port T Code 6
Weight 5.0 LB