Vickers D03 Solenoid Valve

869975

Vickers D03 Solenoid Valve
Item #101854362
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position, 4-Way, Spring Centered Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position, 4-Way, Spring Centered Function

description

  • Industry-standard solenoid valves provide precision directional control for any hydraulic system and can be subplate or manifold mounted.

compliances

  • 0
Spool Center Condition A Port and Double Offset sensing switch on B Port
Spool Shift Timing N/A
Function 3-Position, 4-Way, Spring Centered
Manual Override Option Code None
Model No. DG4V 3 6C M FW H7 60
Housing Code W
Cycle Rate [Max] N/A
Temperature Range [Max] 158 °F
Port Restrictor Plugs None
Compatible Fluids Phosphate Ester Fluids
Mounting Subplate/Manifold Mount
Pressure Port Check Valve Pressure N/A
Operation Solenoid Operated
Seal Material Viton
Mechanical Options None
Port T Pressure Rating 3000 psi
Leakage Standard Performance
NFPA Size D03
Function Code 6
Pilot/Drain None
Surge Suppressor/Damper None
Surge Suppressor/Damper Code None
Temperature Range [Min] -4 °F
AC/DC DC
Crossover P Blocked, A or B to T
Reducer Module No
Port T Code 7
Valve Type High-Performance
Electrical Connection Terminal Box
Spool Spring Arrangement Code C
Body Material Gray Iron
Port Restrictor Plug Code None
Spool Code 6
Electrical Connector Code None
Manual Override Plain Override
Pilot Valve Type N/A
Actuator Type Solenoid
Coil Type Code F
Coil Rating Code H
Center Position P Blocked, A & B to T
Manufacturer Part No. DG4V 3 6C M FW H7 60
Response Type Standard Response
Solenoid Energization Code None
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
EN Code None
Performance Standard Performance
Tank Port Rating 3046
Design No. 60
Solenoid Double
Rated Flow 10.6 gal/min
Fluid Cleanliness 19/17/14 micron
Electrical Options None
Pressure [Max] 5000 psi
Watt Rating 30 W
No. of Stages Single Stage
Overrides No Overrides
Rated Flow [Max] 20 gal/min
Voltage & Frequency 24 VDC
Solenoid Code H
Spool Indicator Switch Code None
Indicator Lights No
Solenoid Indicator Lights Code None
Weight 4.6 LB