Vickers D03 Solenoid Valve

02-110680

Vickers D03 Solenoid Valve
Item #101951658
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset, End To Center, Left Hand Build Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset, End To Center, Left Hand Build Function

description

  • These solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. The 60-design series has been specially designed and developed to cover expanded demands in the industry as well as the many traditional uses of the earlier designs.

features

  • Efficient control of greater hydraulic powers without increasing solenoid power consumption
  • Multi-fluid capability without the need to change seals
  • Solenoid coils can be changed quickly and easily without leakage from the hydraulic system
  • Compact, cost-effective system design when used with Vickers SystemStak valves and subplates
  • Up to 10.5 gpm at 5,000 psi
  • Valve mounting face conforms to ISO 4401, size 03, and is compatible with related international standards
Temperature Range [Min] -4 °F
Surge Suppressor/Damper None
Indicator Lights No
Pressure [Max] 5000 psi
Mechanical Options None
Pilot/Drain None
Actuation Identification Solenoid A
Seal Material Buna-N
Function Code 6
Housing Code W
Operation Solenoid Operated
EN Code None
Response Time 18 to 32 ms
Solenoid Code B
Leakage Standard Performance
Fluid Cleanliness 19/17/14 micron
Model No. DG4V-3S-6BL-M-FW-B5-60
Cycle Rate [Max] N/A
Crossover P Blocked, A or B to T
Pressure Port Check Valve Pressure N/A
Coil Type Code F
Electrical Connection No Connector
Port T Pressure Rating 1500 psi
Performance Standard Performance
No. of Stages Single Stage
Pilot Valve Type N/A
Solenoid Single
Spool Code 6
Electrical Options None
Spool Shift Timing N/A
Design No. 60
Electrical Connector Code None
NFPA Size D03
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Port Restrictor Plug Code None
Body Material Gray Iron
Overrides No Overrides
Voltage & Frequency 110/120 VAC - 50/60 Hz
Rated Flow [Max] 10 gal/min
Spool Spring Arrangement Code B
Reducer Module No
Port Restrictor Plugs None
Valve Type Standard-Duty
Port T Code 5
Function 2-Position Spring Offset, End To Center, Left Hand Build
Solenoid Energization Code None
Solenoid Indicator Lights Code None
Spool Indicator Switch Code None
Coil Rating Code B
Surge Suppressor/Damper Code None
Mounting Subplate/Manifold Mount
AC/DC AC
Compatible Fluids Petroleum Oil
Manual Override Option Code None
Tank Port Rating 1450
Center Position P Blocked, A & B to T
Actuator Type Solenoid
Response Type Standard Response
Temperature Range [Max] 158 °F
Manual Override Plain Override
Weight 5.0 LB