Skip to content Skip to navigation menu
Vickers D05 Solenoid Valve

02-126141

Vickers D05 Solenoid Valve
Item #101973830
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D05 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers D05 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D05 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DGS4S models are direct solenoid operated directional control valves. Their primary function in a hydraulic circuit is to direct fluid flow to a work cylinder or to control the direction of rotation of a hydraulic motor.
  • Port connections are made by mounting the valve on a manifold or subplate containing the interface.
  • Electrical connections to the valve are made in an electrical wiring housing or by various plug-in devices. A ground terminal is provided.

caution

  • Each installation should be designed so that the heated section of the heater is totally immersed at all times to avoid heater failure and/or possible damage to the fluid in the tank
Electrical Connection Lead Wires w/ Terminal Box
No. of Stages Single Stage
Crossover P to A or B, T & A or B Blocked
Actuator Type Solenoid
Tank Port Rating 1000
AC/DC AC
Temperature Range [Max] 122 °F
Rated Flow [Max] 24 gal/min
Body Material Gray Iron
Performance Standard Performance
Mounting Subplate/Manifold Mount
Manual Override Plain Override
Indicator Lights Yes
Cycle Rate [Max] N/A
Actuation Identification Solenoid A, Solenoid B
Electrical Options None
Port Restrictor Plugs None
Coil Type Code None
Design No. 60
NFPA Size D05
Port T Pressure Rating 1000 psi
Spool Spring Arrangement Code C
Function 3-Position Spring Centered
Seal Material Buna-N
Leakage Standard Performance
Pressure [Max] 5000 psi
Solenoid Double
Pressure Port Check Valve Pressure N/A
Operation Solenoid Operated
Valve Type Standard-Duty
Temperature Range [Min] 68 °F
Coil Type Flying Leads
Model No. DG4S4LW-017C-B-60
Mechanical Options None
Mechanical Options Code None
Compatible Fluids Petroleum Oil
Pilot Valve Type N/A
Electrical Options Code LW
Center Position P to A & B, T Blocked
Reducer Module N/A
Overrides No Overrides
Spool Code 7
Pilot/Drain None
Voltage & Frequency 110/120 VAC - 50/60 Hz
Response Type Standard Response
Fluid Cleanliness 19/17/14 micron
Response Time 20 to 40 ms
Coil Rating Code B
Flow Direction Code 4
Surge Suppressor/Damper None
Weight 10.0 LB