Vickers D03 Solenoid Valve

02-145158

Vickers D03 Solenoid Valve
Item #101910069
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position, 4-Way, Spring Centered Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position, 4-Way, Spring Centered Function

description

  • Industry-standard solenoid valves provide precision directional control for any hydraulic system and can be subplate or manifold mounted.

features

  • These valves conform to ISO 4401 size 03, ANSI/B93.7M size D03, CETOP size 3 and NG 6
Watt Rating 20 W
Solenoid Energization Code V
Spool Indicator Switch Code None
Electrical Connection Terminal Box
Solenoid Indicator Lights Code None
Performance Standard Performance
Solenoid Double
Leakage Standard Performance
Fluid Cleanliness 19/17/14 micron
Actuator Type Solenoid
Overrides No Overrides
Mounting Manifold Mount
Manual Override Option Code None
Surge Suppressor/Damper Code None
Reducer Module No
Manufacturer Part No. DG4V 3 8C V M FW B6 61
Design No. 61
Spool Center Condition A Port and Double Offset sensing switch on B Port
Temperature Range [Min] -4 °F
Rated Flow 21.00 gal/min
Spool Spring Arrangement Code C
Port T Pressure Rating 3000 psi
Housing Code W
Seal Material Viton
Coil Type Code F
No. of Stages Single Stage
Voltage & Frequency 110/120 VAC - 50/60 Hz
Surge Suppressor/Damper None
NFPA Size D03
Pilot Valve Type N/A
Temperature Range [Max] 158 °F
Electrical Options None
Operation Solenoid Operated
Mechanical Options None
Solenoid Code B
Port T Code 6
EN Code None
Manual Override Plain Override
Port Restrictor Plugs None
Crossover All Ports Open, Restricted
Coil Rating Code B
Indicator Lights No
Body Material Gray Iron
Response Type Standard Response
Compatible Fluids Phosphate Ester Fluids
Valve Type High-Performance
Function 3-Position, 4-Way, Spring Centered
Spool Code 8
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Function Code 8
Tank Port Rating 3000
Port Restrictor Plug Code None
Pilot/Drain None
Model No. DG4V-3-8C-VM-FW-B6-61
Rated Flow [Max] 20.00 gal/min
Cycle Rate [Max] 0
Pressure Port Check Valve Pressure N/A
Spool Shift Timing N/A
Center Position P to T, A & B Blocked
Electrical Connector Code None
AC/DC AC
Pressure [Max] 5,075 psi
Weight 5.0 LB