Vickers D03 Solenoid Valve

02-146499

Vickers D03 Solenoid Valve
Item #102039938
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset, End To Center, Left Hand Build Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset, End To Center, Left Hand Build Function

description

  • These solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. The 60-design series has been specially designed and developed to cover expanded demands in the industry as well as the many traditional uses of the earlier designs.

features

  • Efficient control of greater hydraulic powers without increasing solenoid power consumption
  • Multi-fluid capability without the need to change seals
  • Solenoid coils can be changed quickly and easily without leakage from the hydraulic system
  • Compact, cost-effective system design when used with Vickers SystemStak valves and subplates
  • Up to 21 gpm at 5,000 psi
  • Valve mounting face conforms to ISO 4401, size 03, and is compatible with related international standards
Function Code 6
Temperature Range [Max] 158 °F
Crossover P Blocked, A or B to T
Pressure [Max] 5000 psi
Valve Type High-Performance
Rated Flow [Max] 20 gal/min
Housing Code W
Surge Suppressor/Damper Code None
Solenoid Energization Code V
Port Restrictor Plug Code None
Mechanical Options None
Surge Suppressor/Damper None
Model No. DG4V-3-6BL-VM-FW-B6-60
Center Position P Blocked, A & B to T
Reducer Module No
Leakage Standard Performance
Seal Material Buna-N
Operation Solenoid Operated
Actuation Identification Solenoid A
Indicator Lights No
NFPA Size D03
Solenoid Single
Electrical Connection No Connector
Manual Override Plain Override
Solenoid Indicator Lights Code None
Spool Code 6
No. of Stages Single Stage
Pilot Valve Type N/A
Compatible Fluids Petroleum Oil
Spool Indicator Switch Code None
Pressure Port Check Valve Pressure N/A
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Performance High Performance
Response Type Standard Response
Spool Shift Timing N/A
Mounting Subplate/Manifold Mount
Coil Type Code F
Coil Rating Code B
Body Material Gray Iron
Tank Port Rating 3046
Response Time 15 to 23 ms
Voltage & Frequency 110/120 VAC - 50/60 Hz
Fluid Cleanliness 19/17/14 micron
Electrical Connector Code None
Design No. 60
Manual Override Option Code None
Port T Code 6
Solenoid Code B
EN Code None
Function 2-Position Spring Offset, End To Center, Left Hand Build
Pilot/Drain None
Port T Pressure Rating 3000 psi
Electrical Options None
Overrides No Overrides
Actuator Type Solenoid
AC/DC AC
Port Restrictor Plugs None
Cycle Rate [Max] N/A
Spool Spring Arrangement Code B
Temperature Range [Min] -4 °F
Weight 5.0 LB