Vickers D03 Solenoid Valve

02-310626

Vickers D03 Solenoid Valve
Item #102088982
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • These solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. The 60-design series has been specially designed and developed to cover expanded demands in the industry as well as the many traditional uses of the earlier designs.

features

  • Efficient control of greater hydraulic powers without increasing solenoid power consumption
  • Multi-fluid capability without the need to change seals
  • Solenoid coils can be changed quickly and easily without leakage from the hydraulic system
  • Compact, cost-effective system design when used with Vickers SystemStak valves and subplates
  • Up to 10.5 gpm at 5,000 psi
  • Valve mounting face conforms to ISO 4401, size 03, and is compatible with related international standards
Response Time 18 to 32 ms
Cycle Rate [Max] N/A
Response Type Standard Response
Tank Port Rating 1450
Spool Shift Timing N/A
Solenoid Indicator Lights Code None
Manual Override Option Code H
Electrical Connector Code None
Operation Solenoid Operated
Function 3-Position Spring Centered
Actuation Identification Solenoid A, Solenoid B
Spool Spring Arrangement Code C
Body Material Gray Iron
No. of Stages Single Stage
Temperature Range [Min] -4 °F
Port T Code 5
NFPA Size D03
Coil Type ISO 4400
Rated Flow [Max] 10 gal/min
Pressure [Max] 5000 psi
Coil Type Code U
EN Code None
Indicator Lights No
Coil Rating Code B
Temperature Range [Max] 158 °F
Fluid Cleanliness 19/17/14 micron
Port Restrictor Plugs None
AC/DC AC
Reducer Module No
Center Position P Blocked, A & B to T
Surge Suppressor/Damper Code None
Mechanical Options None
Pressure Port Check Valve Pressure N/A
Overrides No Overrides
Manual Override Plain Override
Solenoid Double
Electrical Connection DIN 43650
Design No. 60
Pilot/Drain None
Mounting Subplate/Manifold Mount
Actuator Type Solenoid
Crossover P Blocked, A or B to T
Spool Code 6
Function Code 6
Port T Pressure Rating 1500 psi
Model No. DG4V-3S-6C-H-M-U-B5-60
Electrical Options None
Solenoid Energization Code None
Voltage & Frequency 110/120 VAC - 50/60 Hz
Leakage Standard Performance
Performance Standard Performance
Port Restrictor Plug Code None
Housing Code None
Pilot Valve Type N/A
Compatible Fluids Petroleum Oil
Surge Suppressor/Damper None
Spool Indicator Switch Code None
Seal Material Buna-N
Valve Type Standard-Duty
Solenoid Code B
Weight 5.0 LB