- Solenoid Actuated Valve
- Pilot Operated Operation
- D08 NFPA Size
- Double Solenoid
- 3-Position Spring Centered Function
description
- DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.
caution
- It is necessary to use a minimum of one flanged pulley to prevent the belt from riding off
- When the drive is operated on other than horizontal shafts, or when the center distance is greater than eight times the diameter of the smaller pulley on drive ratios less than 3:1, both pulleys should be flanged
- When a drive has three pulleys, at least two should be flanged
- If the drive has more than three pulleys, every other pulley should be flanged
Design No. | 10 |
Pilot Pressure Code | None |
Gauge Port Thread Type | 7/16 - 20 UNF, SAE Thread |
Pilot/Drain | Internal Pilot/External Drain |
Indicator Lights | No |
Solenoid Energization Code | None |
EN Code | None |
Seal Material | Buna-N |
Voltage & Frequency | 110/120 VAC - 50/60 Hz |
Temperature Range [Min] | -40 °F |
Electrical Connector Code | None |
Pressure Port Check Valve Code | K |
Port Restrictor Plugs | None |
Overrides | Plain Override Solenoid Ends |
Pressure [Max] | 5000 psi |
Electrical Options Code | None |
Response Type Code | None |
Reducer Module Code | None |
Surge Suppressor/Damper Code | None |
Operation | Pilot Operated |
Actuation Identification | Solenoid A, Solenoid B |
Mechanical Options | None |
Fluid Cleanliness | 19/17/14 micron |
Pilot Drain Code | None |
Valve Type | Standard-Duty |
Coil Type | Flying Leads, 1/2 in NPT Thread Wiring Housing |
Leakage | Standard Performance |
Pressure Port Check Valve Pressure | 5 psi |
Coil Type Code | F |
Reducer Module | No |
Manual Override | Plain Override |
Actuator Type | Solenoid |
Solenoid | Double |
Gauge Port | SAE-4 |
Body Material | Ductile Iron |
Electrical Connection | No Connector |
Center Position | All Ports Blocked |
Spool Code | 2 |
Solenoid Indicator Lights Code | None |
Rated Flow [Max] | 175 gal/min |
Spool Indicator Switch Code | None |
Port T Pressure Rating | 5000 psi |
Mechanical Options Code | None |
Crossover | All Ports Blocked |
Model No. | DG5V-8-S-2C-K-M-FW-B-10 |
Tank Port Rating | 5000 |
Temperature Range [Max] | 230 °F |
No. of Stages | Two Stage |
Electrical Options | None |
Compatible Fluids | Petroleum Oil |
Coil Rating Code | B |
Function | 3-Position Spring Centered |
NFPA Size | D08 |
Port Restrictor Plug Code | None |
Performance | Standard Performance |
AC/DC | AC |
Mounting | Subplate/Manifold Mount |
Gauge Ports Code | None |
Spool Spring Arrangement Code | C |
Manual Override Option Code | None |
Spool Control Modification Code | None |
Housing Code | W |
Surge Suppressor/Damper | None |
Pilot Valve Type | CETOP 3, Standard Performance |
Response Type | Standard Response |
Pilot Valve Type Code | S |
Weight | 35.0 LB |