Skip to content Skip to navigation menu
Vickers D03 Solenoid Valve

02-336829

Vickers D03 Solenoid Valve
Item #101912656
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • For directing and stopping flow at any point in a hydraulic system. Its primary function is to determine the direction of fluid flow in a work cylinder or control the direction of rotation of a fluid motor. Port connections are made by mounting the valve on a subplate or manifold. The valve has wet armature type solenoids. It is derived from the standard model series DG4V-3S-60.

features

  • Tank line can withstand pressures up to 210 bar (3,000 psi)
  • High thermal shock and impact resistance due to new coil design
  • Minimal pressure drop
  • Scratch-proof override seals
  • Multiple electrical connections
  • High reliability

compliances

  • 0
AC/DC DC
Body Material Gray Iron
Port Restrictor Plugs None
Spool Code 6
Seal Material Buna-N
Mounting Subplate/Manifold Mount
Manual Override Plain Override
Coil Type Code U
Housing Code None
Valve Type Standard-Duty for Mobile Equipment
Indicator Lights No
Electrical Options None
Temperature Range [Max] 158 °F
Center Position P Blocked, A & B to T
Spool Spring Arrangement Code C
Solenoid Energization Code None
Operation Solenoid Operated
Port T Code 7
Performance Standard Performance
Solenoid Indicator Lights Code None
Coil Rating Code H
Solenoid Double
Function 3-Position Spring Centered
Electrical Connection DIN 43650
Overrides No Overrides
Compatible Fluids Petroleum Oil
Actuation Identification Solenoid A, Solenoid B
Solenoid Code H
Pilot/Drain None
Surge Suppressor/Damper None
Cycle Rate [Max] N/A
Temperature Range [Min] -4 °F
Design No. 60
NFPA Size D03
Pressure [Max] 5000 psi
Model No. DG4V-3S-6C-H-M-U-H7-60-EN490
Crossover P Blocked, A or B to T
Mechanical Options None
Voltage & Frequency 24 VDC
Reducer Module No
Pressure Port Check Valve Pressure N/A
Rated Flow [Max] 10 gal/min
Spool Indicator Switch Code None
Actuator Type Solenoid
Coil Type ISO 4400
Port Restrictor Plug Code None
Surge Suppressor/Damper Code None
EN Code EN490
Watt Rating 30 W
No. of Stages Single Stage
Pilot Valve Type N/A
Port T Pressure Rating 3000 psi
Response Time 40 to 60 ms
Leakage Standard Performance
Tank Port Rating 1450
Electrical Connector Code None
Function Code 6
Manual Override Option Code H
Response Type Standard Response
Fluid Cleanliness 19/17/14 micron
Spool Shift Timing N/A
Weight 5.0 LB