- Solenoid Actuated Valve
- Pilot Operated Operation
- D08 NFPA Size
- Double Solenoid
- 3-Position Spring Centered Function
description
- DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.
caution
- Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
Coil Type Code | F |
Leakage | Standard Performance |
Spool Code | 8 |
Port T Pressure Rating | 5000 psi |
Mounting | Subplate/Manifold Mount |
Pilot Drain Code | None |
Body Material | Gray Iron |
Overrides | Plain Override Solenoid Ends |
Gauge Ports Code | None |
Pressure Port Check Valve Pressure | N/A |
EN Code | None |
Mechanical Options | None |
Spool Spring Arrangement Code | C |
Surge Suppressor/Damper Code | None |
Pilot Valve Type Code | S |
Center Position | P to T, A & B Blocked |
NFPA Size | D08 |
Coil Type | Flying Leads, 1/2 in NPT Thread Wiring Housing |
Response Type Code | None |
Rated Flow [Max] | 175 gal/min |
Port Restrictor Plugs | None |
Pilot/Drain | External Pilot/Internal Drain |
Gauge Port | SAE-4 |
Tank Port Rating | 5000 |
Electrical Options Code | None |
Solenoid | Double |
Coil Rating Code | B |
Electrical Connector Code | T |
Reducer Module Code | None |
AC/DC | AC |
Surge Suppressor/Damper | None |
Manual Override | Plain Override |
Model No. | DG5V-8-S-8C-VM-FTWL-B-10 |
Solenoid Energization Code | V |
Function | 3-Position Spring Centered |
Indicator Lights | Yes |
Fluid Cleanliness | 19/17/14 micron |
Seal Material | Buna-N |
Spool Indicator Switch Code | None |
Solenoid Indicator Lights Code | L |
Pressure [Max] | 5000 psi |
Spool Control Modification Code | None |
Port Restrictor Plug Code | None |
Pressure Port Check Valve Code | None |
Valve Type | Standard-Duty |
Mechanical Options Code | None |
No. of Stages | Two Stage |
Response Type | Standard Response |
Pilot Pressure Code | None |
Crossover | All Ports Open, Restricted |
Reducer Module | No |
Voltage & Frequency | 110/120 VAC - 50/60 Hz |
Electrical Options | None |
Design No. | 10 |
Actuator Type | Solenoid |
Performance | Standard Performance |
Operation | Pilot Operated |
Electrical Connection | Wired Terminal Block |
Pilot Valve Type | CETOP 3, Standard Performance |
Housing Code | W |
Compatible Fluids | Petroleum Oil |
Spool Center Condition | A Port and Double Offset sensing switch on B Port |
Gauge Port Thread Type | 7/16 - 20 UNF, SAE Thread |
Manual Override Option Code | None |
Weight | 35.0 LB |