- Solenoid Actuated Valve
- Pilot Operated Operation
- D08 NFPA Size
- Double Solenoid
- 3-Position Spring Centered Function
description
- DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.
caution
- Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
Center Position | Tandem P to T |
Actuator Type | Solenoid |
Mechanical Options Code | None |
Spool Control Modification Code | None |
Coil Type | Flying Leads, 1/2 in NPT Thread Wiring Housing |
Body Material | Ductile Iron |
Surge Suppressor/Damper Code | None |
Pilot Drain Code | None |
Mechanical Options | None |
Mounting | Subplate/Manifold Mount |
Solenoid Indicator Lights Code | L |
Response Type | Fast Response |
Spool Code | 4 |
Reducer Module Code | None |
Model No. | DG5V-8-S-4C-X-VM-FTWL-B-10 |
Spool Spring Arrangement Code | C |
Solenoid | Double |
Seal Material | Buna-N |
Surge Suppressor/Damper | None |
Pilot Valve Type Code | S |
Temperature Range [Max] | 230 °F |
Port T Pressure Rating | 5000 psi |
Gauge Port | SAE-4 |
Design No. | 10 |
Crossover | All Ports Blocked |
Valve Type | Standard-Duty |
Pilot Valve Type | CETOP 3, Standard Performance |
Manual Override Option Code | None |
EN Code | None |
Performance | Standard Performance |
AC/DC | AC |
Spool Indicator Switch Code | None |
Compatible Fluids | Petroleum Oil |
Function | 3-Position Spring Centered |
Manual Override | Plain Override |
Coil Rating Code | B |
NFPA Size | D08 |
Electrical Options | None |
Electrical Options Code | None |
Pressure Port Check Valve Code | None |
Indicator Lights | Yes |
Pilot/Drain | Internal Pilot/External Drain |
Port Restrictor Plugs | None |
Electrical Connection | Wired Terminal Block |
Rated Flow [Max] | 175 gal/min |
Electrical Connector Code | T |
Solenoid Energization Code | V |
Gauge Port Thread Type | 7/16 - 20 UNF, SAE Thread |
Coil Type Code | F |
Housing Code | W |
Temperature Range [Min] | -40 °F |
Tank Port Rating | 5000 |
Gauge Ports Code | None |
Voltage & Frequency | 110/120 VAC - 50/60 Hz |
Fluid Cleanliness | 19/17/14 micron |
Overrides | Plain Override Solenoid Ends |
Operation | Pilot Operated |
Pressure [Max] | 5000 psi |
Reducer Module | No |
No. of Stages | Two Stage |
Leakage | Standard Performance |
Port Restrictor Plug Code | None |
Pilot Pressure Code | None |
Actuation Identification | Solenoid A, Solenoid B |
Pressure Port Check Valve Pressure | N/A |
Response Type Code | X |
Weight | 35.0 LB |