Parker's B3 and B5 series three-way., body ported valves are ideal for controlling larger single-acting cylinders, air bags and vacuum generators. Body ported for in-line, direct pipe porting. The same valve can also be used on Parker's IEM (Inlet/Exhaust Manifold), allowing more than one valve to be mounted on a common base. Featuring Parker's exclusive Wear Compensation System, expect millions of non-lubricated cycles from this valve. Electrical connections are easy using Parker's 15 mm DIN-style connectors. Flush non-locking overrides are standard.
features
IEM (inlet/exhaust manifold)
Factory prelubricated
CE approved
Maximum Performance – low friction, fast response, lower operating pressures and less wear
Long Cycle Life – under pressure, radial expansion of the seal occurs to maintain sealing contact with the value bore
NonLube Service – no lubrication required for continuous valve shifting
Bi-Directional Spool Seals – common spool used for any pressure, including vacuum
Length
5.290 in
Outlet Port
1/4 in NPT
Valve Type
3-Way, 2 Position
Width
1.180 in
Cv Flow
1.4
Engineering Level
C
Port Type
NPT
Temperature Range [Max]
120 °F
Return Type
Spring
Overrides
Flush - Non-Locking Override
Height
2.060 in
Spool Description
Normally Closed
Solenoid
Single
Temperature Range [Min]
5 °F
Port Size
1/4
Series
B5
Installed Options
None
Spool Seal Type
Buna-N
Pilot Source
Internal Pilot Supply - Port 1
Stations
N/A
Coil Style
15 mm 3-Pin DIN 43650C
Operation
Electric
Valve Duty
Standard Duty
Wiring Options
None
Valve Body Style
Inline
Operating Pressure Range
Vacuum to 145 psi
Actuator Type
Solenoid
Voltage Rating
24 VDC
Pilot Exhaust
Vented Pilot Exhaust
Weight
1.0 LB