Parker's B3 and B5 series three-way., body ported valves are ideal for controlling larger single-acting cylinders, air bags and vacuum generators. Body ported for in-line, direct pipe porting. The same valve can also be used on Parker's IEM (Inlet/Exhaust Manifold), allowing more than one valve to be mounted on a common base. Featuring Parker's exclusive Wear Compensation System, expect millions of non-lubricated cycles from this valve. Electrical connections are easy using Parker's 15 mm DIN-style connectors. Flush non-locking overrides are standard.
features
IEM (inlet/exhaust manifold)
Factory prelubricated
CE approved
Maximum Performance – low friction, fast response, lower operating pressures and less wear
Long Cycle Life – under pressure, radial expansion of the seal occurs to maintain sealing contact with the value bore
NonLube Service – no lubrication required for continuous valve shifting
Bi-Directional Spool Seals – common spool used for any pressure, including vacuum
Pilot Source
Internal Pilot Supply - Port 1
Temperature Range [Min]
5 °F
Valve Duty
Standard Duty
Series
B5
Voltage Rating
120 VAC
Coil Style
15 mm 3-Pin DIN 43650C
Valve Body Style
Inline
Operating Pressure Range
Vacuum to 145 psi
Solenoid
Single
Overrides
Flush - Non-Locking Override
Temperature Range [Max]
120 °F
Actuator Type
Solenoid
Length
5.290 in
Spool Description
Normally Closed
Spool Seal Type
Buna-N
Engineering Level
C
Stations
N/A
Port Size
3/8
Valve Type
3-Way, 2 Position
Operation
Electric
Height
2.060 in
Wiring Options
None
Port Type
NPT
Outlet Port
3/8 in NPT
Pilot Exhaust
Vented Pilot Exhaust
Width
1.180 in
Installed Options
None
Cv Flow
1.4
Return Type
Spring
Weight
1.0 LB
We're here for you