spring-return valves will return to normal position when released. These valves may be oriented in any position and inline, foot, or panel mounted. Valves are prelubricated so air line lubrication is not necessary but is recommended for longest service life.
These valves are used to operate single-acting cylinders or to provide pilot signals to larger valves. Pushing the button shifts the valve. Manual-return valves will remain in position until the button is pulled
features
Lubricated or nonlubricated service
Temperature range from 32 °F to 175 °F
Vacuum to 145 psig
Valve Duty
Standard Duty
Coil Style
No Coil
Voltage Rating
No Coil
Return Type
Spring
Stations
N/A
Temperature Range [Min]
32 °F
Overrides
No Overrides
Operating Pressure Range
0 psi to 150 psi
Cv Flow
0.17
Operation
Manual
Temperature Range [Max]
175 °F
Port Type
NPT
Series
Directair 2 Series
Valve Type
3-Way, 2 Position
Wiring Options
None
Solenoid
N/A
Spool Description
Normally Closed
Installed Options
None
Valve Body Style
Body Ported
Actuator Type
Palm w/ Button
Port Size
1/8
Lights
No
Weight
1.0 LB