- Solenoid Actuated Valve
- Pilot Operated Operation
- D08 NFPA Size
- Double Solenoid
- 3-Position Spring Centered Function
description
- DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.
caution
- It is necessary to use a minimum of one flanged pulley to prevent the belt from riding off
- When the drive is operated on other than horizontal shafts, or when the center distance is greater than eight times the diameter of the smaller pulley on drive ratios less than 3:1, both pulleys should be flanged
- When a drive has three pulleys, at least two should be flanged
- If the drive has more than three pulleys, every other pulley should be flanged
Spool Spring Arrangement Code | C |
Seal Material | Buna-N |
Rated Flow [Max] | 175 gal/min |
Overrides | Plain Override Solenoid Ends |
Electrical Options | None |
Reducer Module | No |
Port Restrictor Plugs | None |
Compatible Fluids | Petroleum Oil |
Electrical Options Code | None |
Port T Pressure Rating | 5000 psi |
Gauge Ports Code | None |
Body Material | Gray Iron |
Center Position | P Blocked, A & B to T |
Tank Port Rating | 5000 |
Pilot Drain Code | None |
Pressure Port Check Valve Pressure | N/A |
Pilot Valve Type Code | H |
Manual Override Option Code | None |
Reducer Module Code | None |
Housing Code | W |
Surge Suppressor/Damper Code | None |
Pilot Pressure Code | None |
Solenoid Energization Code | None |
Function | 3-Position Spring Centered |
Response Type Code | None |
Fluid Cleanliness | 19/17/14 micron |
Valve Type | Standard-Duty |
Surge Suppressor/Damper | None |
EN Code | None |
Coil Rating Code | B |
Leakage | Standard Performance |
Pilot Valve Type | CETOP 3, High Performance |
Solenoid | Double |
Design No. | 10 |
Spool Indicator Switch Code | None |
Spool Center Condition | A Port and Double Offset sensing switch on B Port |
Indicator Lights | No |
Gauge Port | SAE-4 |
Spool Control Modification Code | None |
Spool Code | 6 |
Coil Type | Flying Leads, 1/2 in NPT Thread Wiring Housing |
Coil Type Code | F |
NFPA Size | D08 |
Actuator Type | Solenoid |
Pilot/Drain | External Pilot/Internal Drain |
No. of Stages | Two Stage |
Performance | High Performance |
Pressure Port Check Valve Code | None |
Solenoid Indicator Lights Code | None |
Port Restrictor Plug Code | None |
Mounting | Subplate/Manifold Mount |
Model No. | DG5V-8-H-6C-M-FW-B-10 |
AC/DC | AC |
Pressure [Max] | 5000 psi |
Mechanical Options | None |
Mechanical Options Code | None |
Crossover | P Blocked, A or B to T |
Gauge Port Thread Type | 7/16 - 20 UNF, SAE Thread |
Voltage & Frequency | 110/120 VAC - 50/60 Hz |
Manual Override | Plain Override |
Electrical Connection | No Connector |
Operation | Pilot Operated |
Response Type | Standard Response |
Electrical Connector Code | None |
Weight | 35.0 LB |