- Pressure Control Valve
- Sequence Valve Type
- Proportional Actuation Option
- 51 to 1000 psi Pressure Adjustment Range
- Screw Adjustment Type
description
- Single-stage valves operate by the application of pressure on the end of the valve spool, acting against a spring which is loaded by means of the manual adjustment mechanism.
- The spool is offset by the spring such that flow cannot pass through the valve.When the force exerted by the pilot pressure on the spool end exceeds the force of the main spring, the spool is moved to allow flow through the valve.
| Interface | D03 |
| Seal Material | Buna-N |
| Design No. | 40 |
| Family Name | Vickers D03 SystemStak™ Valves |
| Valve Type | Sequence Valve "P" Port |
| Model No. | DGMR1-3-PP-BW-S-40 |
| Body Material | Cast Iron |
| Operating Pressure [Max] | 4500 psi |
| Adjustment Type | Screw |
| Gage Port | SAE-4 |
| Actuation Option | Proportional |
| Manufacturer Part No. | DGMR1-3-PP-BW-S-40 |
| Adjustment | Yes |
| Performance | Standard Performance |
| External Drain | No |
| Pressure Adjustment Range (psi) | 51 to 1,000 |
| Flow [Max] | 16 gal/min |
| Electrical Connection | Conduit Box |
| Pressure [Max] | 4500 psi |
| Gauge Port Thread Type | SAE |
| Weight | 2.6 LB |