Vickers D05 Solenoid Valve
Item #101994823
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D05 NFPA Size
  • Single Solenoid
  • 2-Position Spring Centered, End to Center, Single End Function
Vickers by Danfoss02-126355
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D05 NFPA Size
  • Single Solenoid
  • 2-Position Spring Centered, End to Center, Single End Function

description

  • DGS4S models are direct solenoid operated directional control valves. Their primary function in a hydraulic circuit is to direct fluid flow to a work cylinder or to control the direction of rotation of a hydraulic motor.
  • Port connections are made by mounting the valve on a manifold or subplate containing the interface.
  • Electrical connections to the valve are made in an electrical wiring housing or by various plug-in devices. A ground terminal is provided.

caution

  • Not intended for use in most cyclic applications or high speed engagement
  • Tooth clutches are normally engaged when stationary
Voltage & Frequency 24 VDC
Port Restrictor Plugs None
Valve Type Standard-Duty
Watt Rating 30 W
Crossover All Ports Blocked
Mounting Subplate/Manifold Mount
Design No. 60
Center Position All Ports Blocked
Pilot/Drain None
Pressure [Max] 5000 psi
Overrides No Overrides
Temperature Range [Min] 68 °F
Surge Suppressor/Damper None
Port T Pressure Rating 1000 psi
Mechanical Options Code None
Reducer Module N/A
Pressure Port Check Valve Pressure N/A
Coil Type Code U
Operation Solenoid Operated
Manual Override Plain Override
Body Material Gray Iron
Flow Direction Code 4
Temperature Range [Max] 122 °F
Spool Spring Arrangement Code B
Model No. DG4S4-012B-U-H-60
Cycle Rate [Max] N/A
Electrical Options Code None
Coil Rating Code H
No. of Stages Single Stage
Rated Flow [Max] 24 gal/min
AC/DC DC
Tank Port Rating 1000
Response Time 50 to 80 ms
Pilot Valve Type N/A
Actuation Identification Solenoid B
NFPA Size D05
Mechanical Options None
Actuator Type Solenoid
Leakage Standard Performance
Function 2-Position Spring Centered, End to Center, Single End
Solenoid Single
Electrical Connection DIN 43650
Compatible Fluids Petroleum Oil
Performance Standard Performance
Electrical Options None
Spool Code 2
Indicator Lights No
Coil Type ISO 4400 (Din 43650) Connector
Seal Material Buna-N
Response Type Standard Response
Fluid Cleanliness 19/17/14 micron
Weight 10.0 LB