Skip to content Skip to navigation menu
Vickers by Danfoss02-134709

02-134709

Vickers D07 Solenoid Valve
Item #102023417
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D07 NFPA Size
  • Double Solenoid
  • 3-Position Detented Function
Vickers by Danfoss02-134709
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D07 NFPA Size
  • Double Solenoid
  • 3-Position Detented Function

description

  • Two-stage directional valves with an integrally mounted DG4V-3(S)-60 pilot valve. These valves are generally used to control the direction of flow in a hydraulic circuit. This in turn would control the movement of a work cylinder or the rotation of a fluid motor.

applications

  • Suitable for the most demanding industrial applications with flow capacities up to 227 l/min (60 U.S. gpm) and rated pressure of 210 bar (3,000 psi)

features

  • Solid cast body and core passages for maximum strength and minimal pressure drop
Coil Type 1/2 in NPT Thread Wiring Housing
Pilot Drain Code None
Mounting Screw Option Code N/A
Pressure Port Check Valve Code None
Body Material Gray Iron
Manual Override Plain Override
Manual Override Option Code None
Solenoid Energization Code None
Actuator Type Solenoid
Spool Code 2
Electrical Options None
Overrides Plain Override Solenoid Ends
Spool Spring Arrangement Code N
Pressure Port Check Valve Pressure N/A
Solenoid Double
Seal Material Buna-N
Port T Pressure Rating 1450 psi
Assembly Code None
Electrical Connector Code None
Tank Port Rating 1450
Spool Indicator Switch Code None
Mounting Subplate/Manifold Mount
Rated Flow [Max] 60 gal/min
Center Position All Ports Blocked
AC/DC AC
Voltage & Frequency 110/120 VAC - 50/60 Hz
NFPA Size D07
Leakage Standard Performance
No. of Stages Two Stage
Pilot Valve Type N/A
Solenoid Indicator Lights Code None
Coil Type Code F
EN Code None
Port Restrictor Plug Code None
Pressure [Max] 3000 psi
Coil Rating Code B
Performance Standard Performance
Pilot/Drain External Drain
Indicator Lights No
Fluid Cleanliness 19/17/14 micron
Spool Control Modification Code None
Operation Solenoid Operated
Mechanical Options None
Electrical Connection No Connector
Response Type Code None
Pilot Pressure Code None
Model No. DG5S4-042N-M-FW-B5-60
Port Restrictor Plugs None
Valve Type Standard-Duty
Crossover All Ports Blocked
Reducer Module N/A
Housing Code W
Compatible Fluids Petroleum Oil
Electrical Options Code None
Function 3-Position Detented
Design No. 60
Surge Suppressor/Damper None
Response Type Standard Response
Pilot Valve Tank Pressure Rating Code 5
Actuation Identification Solenoid A, Solenoid B
Weight 15.0 LB
We're here for you
with Service Centers across the country -
We have your back
Close Compare List Open Compare List Toggle

Product Comparison