Vickers D03 Solenoid Valve

02-136069

Vickers D03 Solenoid Valve
Item #102035622
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset, End To Center, Left Hand Build Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset, End To Center, Left Hand Build Function

description

  • These solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. The 60-design series has been specially designed and developed to cover expanded demands in the industry as well as the many traditional uses of the earlier designs.

features

  • Efficient control of greater hydraulic powers without increasing solenoid power consumption
  • Multi-fluid capability without the need to change seals
  • Solenoid coils can be changed quickly and easily without leakage from the hydraulic system
  • Compact, cost-effective system design when used with Vickers SystemStak valves and subplates
  • Up to 10.5 gpm at 5,000 psi
  • Valve mounting face conforms to ISO 4401, size 03, and is compatible with related international standards
Seal Material Buna-N
EN Code EN21
Model No. DG4V-3S-0BL-M-FW-B5-60-EN21
Housing Code W
Fluid Cleanliness 19/17/14 micron
Body Material Gray Iron
Voltage & Frequency 110/120 VAC - 50/60 Hz
Pressure [Max] 5000 psi
Temperature Range [Min] -4 °F
Tank Port Rating 1450
Spool Indicator Switch Code None
Port T Pressure Rating 1500 psi
Coil Rating Code B
Electrical Connector Code None
Spool Shift Timing N/A
Function Code 0
NFPA Size D03
Rated Flow [Max] 10 gal/min
Spool Code 0
Coil Type Code F
Surge Suppressor/Damper Code None
Port Restrictor Plug Code None
Valve Type Standard-Duty
Mounting Subplate/Manifold Mount
Temperature Range [Max] 158 °F
Actuation Identification Solenoid A
Actuator Type Solenoid
Port Restrictor Plugs None
Spool Spring Arrangement Code B
Response Time 18 to 32 ms
Pilot Valve Type N/A
Leakage Standard Performance
Manual Override Plain Override
Electrical Connection No Connector
Overrides No Overrides
Indicator Lights No
Solenoid Single
AC/DC AC
Electrical Options None
Mechanical Options None
Compatible Fluids Petroleum Oil
Pressure Port Check Valve Pressure N/A
Solenoid Code B
Center Position All Ports Open
No. of Stages Single Stage
Cycle Rate [Max] N/A
Solenoid Energization Code None
Design No. 60
Manual Override Option Code None
Solenoid Indicator Lights Code None
Pilot/Drain None
Response Type Standard Response
Crossover All Ports Open
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Surge Suppressor/Damper None
Reducer Module No
Function 2-Position Spring Offset, End To Center, Left Hand Build
Port T Code 5
Performance Standard Performance
Operation Solenoid Operated
Weight 5.0 LB